An Innovative Control Strategy to Improve the Fault Ride-Through Capability of DFIGs Based on Wind Energy Conversion Systems

Lê Văn Đại, Xinran Li, Yong Li, Trần Lê Thăng Đồng, Caoquyen LeEnergies 2016 · DOI

TL;DR

This paper introduces a novel control strategy for Doubly Fed Induction Generators (DFIGs) in wind energy systems to significantly improve their ability to withstand grid voltage dips (Low Voltage Ride-Through or LVRT). By employing passivity theory for the rotor-side converter and a new two-term approach for the grid-side converter, the proposed method enhances system stability and power quality during grid faults, outperforming conventional methods.

What Problem Does This Paper Address?

The increasing penetration of wind energy into power grids presents challenges, particularly concerning the stability of wind turbines during grid disturbances like voltage dips. Doubly Fed Induction Generators (DFIGs), a popular choice for wind turbines due to their efficiency and cost-effectiveness, are highly sensitive to these grid faults. During a fault, voltage dips can lead to over-currents and over-voltages in the DFIG's components, potentially causing damage and leading to a loss of control. Grid codes now mandate that wind turbines must remain connected and continue to supply power during such events, making robust LVRT capability a critical requirement. Existing solutions often involve complex hardware or less effective control strategies, prompting the need for an improved, integrated control approach.

Methods

The paper proposes an innovative control strategy that targets both the Rotor Side Converter (RSC) and the Grid Side Converter (GSC) of a DFIG-WECS.

  • Rotor Side Converter (RSC) Control: Instead of traditional PI controllers, the RSC's current control loops are redesigned using passivity theory. This approach leverages the inherent non-linear properties of the generator to ensure better tracking of mechanical and electrical reference values, leading to more effective capture of wind energy and faster, more accurate tracking of generator speed and current.
  • Grid Side Converter (GSC) Control: A novel two-term approach is introduced for the GSC to maintain a stable DC-link voltage.
  • Reference Reactive Current: The first term incorporates a reference reactive current based on the maximum voltage rating of the GSC.
  • Disturbance Compensation: The second term addresses the instantaneous unbalanced power flow between the RSC and GSC. It acts as a disturbance compensation signal, considering the instantaneous power of the grid filter to counteract fluctuations in rotor power.

This integrated strategy aims to limit DC-link voltage fluctuations, reduce peak rotor and stator currents, and ensure continuous active and reactive power supply to the grid during severe faults, all without requiring additional protective hardware.

Datasets

Not discussed in the paper. The study relies on time-domain simulations using PSCAD/EMTP.

Key Insights and Ideas

  • Passivity Theory for RSC: Applying passivity theory to the RSC's current control loops is a novel way to improve DFIG stability during faults, moving beyond conventional PI controllers. This leverages fundamental system dynamics for robust control.
  • Two-Term GSC Control: The proposed two-term GSC control, which explicitly accounts for instantaneous power imbalances and grid filter dynamics, offers a more sophisticated way to manage DC-link voltage compared to simpler approaches.
  • Integrated Control: The paper emphasizes the benefit of a coordinated control strategy for both RSC and GSC, rather than treating them independently, to achieve superior LVRT performance.
  • Hardware-Agnostic Improvement: The strategy achieves enhanced LVRT without requiring additional protective hardware like crowbars or choppers, potentially reducing system cost and complexity.

Key Results

Simulations of a 2.0 MW-575 V DFIG-WECS using PSCAD/EMTP demonstrated the effectiveness of the proposed control strategy.

  • Improved LVRT Capability: The proposed strategy significantly improved the LVRT capability compared to a conventional control method.
  • Reduced Oscillations: Oscillations in active and reactive power, rotor and stator currents, and DC-link voltage were significantly reduced.
  • Faster Damping: The system reached its steady-state faster after fault clearance.
  • Within Thresholds: Under various symmetrical and asymmetrical fault scenarios, key parameters like DC-link voltage, stator, and rotor currents remained within acceptable limits, avoiding the activation of protective devices like the DC-chopper and crowbar. For instance, in the first scenario, the DC-link voltage did not exceed 1.115 p.u., and stator/rotor currents stayed below 0.98/1.11 p.u., respectively.

Limitations and Future Work

  • Simulation-Based: The study's findings are based on time-domain simulations. While PSCAD/EMTP is a robust tool, real-world implementation might reveal additional complexities.
  • Specific System: The proposed strategy was tested on a specific 2.0 MW DFIG-WECS. Further validation on different DFIG sizes and grid configurations would be beneficial.
  • Parameter Sensitivity: The paper does not extensively discuss the sensitivity of the proposed control strategy to parameter variations in the DFIG or the grid.

The authors suggest that the proposed control strategy can be further applied to enhance the LVRT capability of DFIG-WECS, implying potential for broader application and further refinement.

Summary updated

Abstract

An innovative control strategy is proposed for enhancing the low voltage ride-through (LVRT) capability of a doubly fed induction generator based on wind energy conversion systems (DFIG-WECS). Within the proposed control method, the current control loops of the rotor side converter (RSC) are developed based on passivity theory. The control scheme for the grid side converter (GSC) is designed based on a two-term approach to keep the DC-link voltage close to a given value. The first term based on the maximal voltage of GSC is introduced in the GSC control loops as a reference reactive current. The second one reflecting the instantaneous unbalanced power flow between the RSC and GSC is also introduced in the GSC control loops as a disturbance considering the instantaneous power of the grid filter to compensate the instantaneous rotor power. The effectiveness of the proposed control strategy is verified via time domain simulation of a 2.0 MW-575 V DFIG-WECS using PSCAD/EMTP. Simulation results show that the control of the DFIG with the proposed approach can improve the LVRT capability better than with the conventional one.
BibTeX
@inproceedings{ai2016innovative,
  author = {Lê Văn Đại and Xinran Li and Yong Li and Trần Lê Thăng Đồng and Caoquyen Le},
  title = {{An Innovative Control Strategy to Improve the Fault Ride-Through Capability of DFIGs Based on Wind Energy Conversion Systems}},
  booktitle = {Energies},
  year = {2016},
  doi = {10.3390/en9020069},
}
Figure