An incremental deformation model of arterial dissection

Beibei Li, Steven Roper, Lei Wang, Xiaoyu Luo, N. A. HillJournal of Mathematical Biology 2018 · DOI

Abstract

We develop a mathematical model for a small axisymmetric tear in a residually stressed and axially pre-stretched cylindrical tube, with direct application to aortic dissection. The artery is idealized as a single-layer thick-walled axisymmetric hyperelastic tube reinforced with collagen fibers, modeled using the Holzapfel-Gasser-Ogden strain-energy function. The tear is treated as an incremental deformation of this pre-stressed tube. Our numerical results indicate that decreasing the fiber angle, decreasing axial pre-stretch, and increasing the opening angle (residual stress) all tend to widen the dissection.

Introduction: The Mechanics of Aortic Dissection

Aortic dissection is a life-threatening cardiovascular event characterized by a tear in the inner layer of the aorta. This allows blood to penetrate the arterial wall, creating a "false lumen" that can compress the true lumen and lead to organ failure or catastrophic rupture.

Anatomy of an aortic dissection, showing the tear in the arterial wall and the resulting false lumen.

While the clinical risks are well-documented, modeling the biomechanical behavior of these tears is challenging. Arteries are complex, non-linear, and "pre-stressed" structures. Most existing models simplify the geometry or ignore the residual stress that exists even in the absence of blood flow. This study addresses these gaps by applying incremental deformation theory to a sophisticated hyperelastic model of the arterial wall.

Modeling Approach

The researchers treat the artery as a thick-walled, incompressible, hyperelastic cylinder. To capture the anisotropic behavior of the tissue, they employ the Holzapfel–Gasser–Ogden (HGO) strain-energy function, which accounts for both the soft tissue matrix and the stiffening effect of collagen fibers.

The idealized thick-walled single-layer cylindrical model, showing the opening angle α, collagen fiber angle β, and the sequence from reference to incremental deformation.

The model incorporates several key physiological features:

  • Residual Stress Modeling: Represented via an "opening angle" (α), which captures the tendency of an arterial ring to spring open when cut to relieve internal tension.
  • Incremental Deformation: The tear is modeled as a small perturbation or incremental change to the equilibrium state of the intact, pre-stressed artery.
  • Mathematical Framework: Fourier transforms convert partial differential equations into ordinary differential equations, which are solved numerically using MATLAB’s bvp4c routine.

Key Insights and Results

The study reveals how tissue architecture and physiological stresses dictate the severity of an arterial tear:

  • The "Staple" Effect of Fibers: Collagen fibers act as mechanical reinforcements. When fibers are aligned more axially (longitudinally), they resist the opening of the tear. Conversely, a more circumferential alignment (lower fiber angle β) significantly worsens the "gaping" of the dissection.
  • The Danger of "Slack" Arteries: Arteries are naturally under longitudinal tension in the body. The model finds that decreasing this axial pre-stretch—a common occurrence with aging—makes the dissection much wider and less stable.
  • The Residual Stress Paradox: While residual stress typically helps distribute pressure evenly in healthy arteries, this model suggests that higher residual stress (a larger opening angle) actually promotes wider tears once a dissection has initiated.
  • Pressure Sensitivity: Even a small incremental increase in blood pressure (1 kPa) was found to significantly bulge the arterial wall and expand the dissection, highlighting the critical importance of blood pressure management.

The model's accuracy was validated against standard finite element analysis (FEAP), showing a high degree of agreement (within 4%) for small tears.

Limitations and Future Directions

This study provides a rigorous framework but includes several simplifications. The model treats the arterial wall as a single layer (the media), whereas real arteries have three distinct layers with varying properties. Additionally, the model is static and assumes axisymmetry.

Future research will focus on modeling propagation—the process by which a tear "zips" open along the vessel. Incorporating a "cohesive zone model" could eventually allow clinicians to predict which patients are at the highest risk of catastrophic arterial failure based on their specific tissue architecture.

Summary updated

Abstract

We develop a mathematical model for a small axisymmetric tear in a residually stressed and axially pre-stretched cylindrical tube. The residual stress is modelled by an opening angle when the load-free tube is sliced along a generator. This has application to the study of an aortic dissection, in which a tear develops in the wall of the artery. The artery is idealised as a single-layer thick-walled axisymmetric hyperelastic tube with collagen fibres using a Holzapfel-Gasser-Ogden strain-energy function, and the tear is treated as an incremental deformation of this tube. The lumen of the cylinder and the interior of the dissection are subject to the same constant (blood) pressure. The equilibrium equations for the incremental deformation are derived from the strain energy function. We develop numerical methods to study the opening of the tear for a range of material parameters and boundary conditions. We find that decreasing the fibre angle, decreasing the axial pre-stretch and increasing the opening angle all tend to widen the dissection, as does an incremental increase in lumen and dissection pressure.
BibTeX
@article{li2018incremental,
  author = {Beibei Li and Steven Roper and Lei Wang and Xiaoyu Luo and N. A. Hill},
  title = {{An incremental deformation model of arterial dissection}},
  journal = {Journal of Mathematical Biology},
  year = {2018},
  doi = {10.1007/s00285-018-1309-8},
}
Figure