Introduction
High-altitude Electromagnetic Pulses (HEMP) pose a significant threat to critical infrastructure, particularly long overhead power lines and communication cables. These pulses couple with the lines, inducing massive transient surges that can damage connected Equipment Under Test (EUT). To ensure resilience, engineers employ Pulsed Current Injection (PCI) testing, where simulated surges are injected directly into device ports.
However, current international standards often fail to account for the complex, non-linear, or high-impedance characteristics of real-world EUTs. Standard tests typically assume a simple short-circuit impedance, which can lead to significant inaccuracies—either over-stressing the equipment or failing to identify critical vulnerabilities. Because measuring exact EUT impedance under high-current, high-bandwidth conditions is extremely difficult, there is a pressing need for an "impedance-independent" testing methodology.
Methodology: The Two-Port Network Approach
The researchers developed a novel model based on Baum-Liu-Tesche (BLT) equations to decouple the HEMP excitation from the specific electrical characteristics of the EUT. The core of this approach involves replacing the complex field-to-line coupling process with equivalent lumped sources.
By modeling the injection region as a two-port network, the authors demonstrated that a specific combination of series voltage sources and parallel current sources can replicate the real-world HEMP response regardless of the EUT's input impedance. This theoretical framework allows for the design of PCI test setups that do not require prior knowledge of the device's internal impedance.
To bridge the gap between theory and hardware, the model simplifies complex theoretical waveforms into practical "double-exponential" pulses compatible with standard Marx generators. This simplification is governed by "Time-Waveform Norms"—specifically Peak Voltage ($N_1$), Peak Rate of Rise ($N_2$), and Root Action ($N_3$)—ensuring that the simplified test pulse remains conservative and valid.
Validation and Results
The model was validated through numerical simulations of a 2000m long overhead line (10m height) exposed to a standard 50 kV/m Bell Laboratory HEMP waveform. The simulation compared the theoretical field-to-line coupling against the voltage generated by the proposed PCI model at the EUT port.
The results demonstrated exceptional accuracy. The voltage waveforms produced by the PCI model were nearly identical to those from the theoretical coupling. Furthermore, the simplified PCI generators maintained a slight safety margin across all key stress norms, ensuring the test is sufficiently rigorous without being unrealistic. For instance, the peak voltage ($N_1$) was measured at 10.3 kV for the PCI model compared to 10.2 kV for the theoretical coupling.
Conclusion
This research provides a robust, impedance-independent framework for HEMP testing on long lines. By utilizing a two-port network model and norm-based equivalence, the proposed method eliminates the need for difficult impedance measurements and provides a more reliable simulation of real-world electromagnetic interference. Future work will focus on physical laboratory validation to confirm these findings with non-linear hardware and real-world couplers.
Summary updated