An Automated Inner Dimensional Measurement System Based on a Laser Displacement Sensor for Long-Stepped Pipes

Fumin Zhang, Xinghua Qu, Jianfei Ouyang2012 · DOI

TL;DR

This paper introduces an automated system for precisely measuring the internal 3D geometry of large, long, and stepped pipes, a challenging task for traditional methods. By combining a laser displacement sensor with a mobile vehicle and a novel fixing mechanism, the system achieves high accuracy (0.02 mm expanded uncertainty) and repeatability (1.1 µm) for diameters up to 600 mm.

What Problem Does This Paper Address?

Measuring the internal dimensions of large-diameter pipes, especially those used in critical infrastructure like nuclear power plants and ships, is crucial for quality control and assembly. However, these pipes are often too long and narrow for human access, making conventional tools like CMMs or micrometers impractical. Existing automated solutions often struggle with the complexities of stepped pipes, where changes in diameter can cause measurement systems to tilt, leading to elliptical data and reduced accuracy. Furthermore, the wide variation in pipe diameters requires adaptable measurement approaches. This paper aims to bridge this gap by presenting a robust, automated system capable of high-precision measurement in such challenging environments.

Methods

The core of the system is a laser displacement sensor mounted on an extended arm. This arm is attached to a motorized carriage that moves within the pipe. To overcome the limited range of the laser sensor, the arm is rotated 360 degrees around the pipe's axis, effectively scanning the inner surface. The system utilizes a cylindrical coordinate measurement method, converting polar data to Cartesian coordinates for analysis.

A key innovation is the "fixing and centering mechanism" which uses a pantograph design with six legs. This mechanism ensures the measurement system remains concentric with the pipe's axis, even in the presence of stepped holes, thus preventing the acquisition of elliptical data. The system also incorporates axial forward-backward walk units for maneuvering along the pipe. Data acquisition and system control are managed wirelessly via a PC, enabling remote operation. Systematic errors related to arm length, tilt, and offset are meticulously analyzed and calibrated.

Datasets

Not discussed in the paper. The paper focuses on the development and validation of a measurement system using sample parts and field experiments.

Key Insights and Ideas

  • Stepped Pipe Challenge Solved: The novel fixing and centering mechanism is crucial for maintaining coaxial alignment, preventing the common issue of elliptical data acquisition in stepped pipes. This is a significant advancement for automated pipe inspection.
  • Extended Arm for Large Diameters: Using a laser sensor with a small measurement range on an extended arm is an effective strategy to achieve high accuracy for large diameters, overcoming the limitations of sensors with inherently larger ranges.
  • Systematic Error Calibration is Key: The paper emphasizes the importance of identifying and calibrating systematic errors (arm length, tilt, offset) to achieve high measurement accuracy. This rigorous approach is essential for metrology applications.
  • Warm-up Time is Critical: The study highlights the significant impact of sensor warm-up time on measurement stability, demonstrating a noticeable drift in the initial 26 minutes of operation. This is a practical consideration for real-world deployment.

Key Results

  • Accuracy: The system achieves an expanded uncertainty of 0.02 mm at a 95% confidence probability for diameters up to 600 mm.
  • Repeatability: A repeatability test shows a standard deviation of 1.1 µm after the system has warmed up, indicating excellent precision.
  • Field Performance: In field tests on pipes with diameters of 605 mm, the maximum deviation after calibration was 9 µm, and the deviation between two sensors was 4 µm, demonstrating good performance in real-world conditions.
  • Laser Tracker Comparison: Measurements were validated against a laser tracker, showing a maximum deviation of 6 µm in laboratory tests.

Limitations and Future Work

  • Warm-up Phase: The paper acknowledges the significant warm-up time (approximately 26 minutes) required for the laser sensor to stabilize. While compensated for, this is a practical limitation for rapid deployment.
  • Assembly Parameter Alteration: In field measurements, changes in arm and leg lengths due to assembly on-site can lead to altered assembly parameters, necessitating recalibration.
  • Future Work: The authors suggest that the measurement range of the system can be extended to greater than 1,000 mm by increasing the length of the legs and arms, indicating a clear path for future development.