NeurIPS 2026Coming to NeurIPS?Explore papers, orals & directions

AI Use in Mammography for Diagnosing Metachronous Contralateral Breast Cancer

Mio Adachi, Tomoyuki Fujioka, Toshiyuki Ishiba, Miyako Nara, Sakiko Maruya, Kumiko Hayashi, Yuichi Kumaki, Emi Yamaga, Leona Katsuta, Du Hao, Mikael Hartman, Mengling Feng, Goshi Oda, Kazunori Kubota, Ukihide TateishiJ. Imaging 2024 · DOI

TL;DR

This study investigates the potential of an AI system (FxMammo™) to improve the detection of metachronous contralateral breast cancer (MCBC) on mammograms, a challenging diagnosis. The AI system demonstrated promising results, identifying potential malignancies in cases missed by radiologists and even detecting cancer earlier than conventional methods in a small cohort of patients.

What Problem Does This Paper Address?

Detecting metachronous contralateral breast cancer (MCBC) – the development of cancer in the opposite breast after an initial diagnosis – is a significant clinical challenge. Mammography (MG), the primary screening tool, can be less effective in dense breast tissue, common in Asian women, and interpreting post-surgical changes further complicates diagnosis. Current surveillance guidelines often rely on physical exams and MG, with limited endorsement for advanced imaging like MRI, especially in regions where it's not routinely covered by insurance. This gap highlights the need for more sensitive and accurate diagnostic tools to aid radiologists in identifying MCBC earlier, potentially improving patient outcomes.

Methods

The researchers employed a retrospective study design, analyzing mammography data from 10 patients who had undergone unilateral breast cancer surgery and subsequently developed contralateral breast cancer. The core of their methodology involved evaluating the performance of an AI-powered mammography diagnostic support system, FxMammo™ (FathomX Pte Ltd., Singapore). This AI system, built on deep learning (VGG-16 network and CNNs), quantifies malignancy probability and highlights areas of interest on mammograms. The AI's diagnoses were compared against the interpretations of Japanese radiologists, who assessed the images using BI-RADS categories. For discrepancies, images and pathology reports were reviewed in detail. The study also analyzed prior mammograms to assess the AI's ability to detect cancer earlier.

Datasets

The FxMammo™ AI model was trained on a dataset of 17,769 mammography cases, with 45% being malignant, collected from 10 institutions across Asia. For this specific study, the evaluation dataset comprised mammography images from 10 patients with metachronous contralateral breast cancer, all of whom were Japanese females.

Key Insights and Ideas

  • AI as a "Second Pair of Eyes": The AI system proved valuable in identifying potential malignancies that radiologists initially overlooked, suggesting it can act as a crucial adjunct to human interpretation.
  • Early Detection Potential: In a notable finding, the AI system identified signs of malignancy a year before the conventional diagnosis in some cases, underscoring its potential for earlier detection.
  • Addressing Diagnostic Complexity: The AI's ability to analyze images and highlight areas of interest could be particularly beneficial in the complex scenario of post-surgical changes, where traditional comparative analysis is challenging.
  • Mimicking Human Patterns: The researchers hypothesize that the AI's effectiveness might stem from its training data, which likely reflects human diagnostic patterns, allowing it to mimic radiologists' reasoning.

Key Results

  • Improved Detection Rate: The AI system identified malignancies in 60% (6 out of 10) of the cases, compared to 50% (5 out of 10) by radiologists.
  • Sole AI Diagnosis: Two cases (20%) were diagnosed solely by the AI system, with radiologists finding no signs of malignancy.
  • Earlier Diagnosis: For two of these cases, the AI system had identified malignancies a year prior to the conventional diagnosis.
  • Overall Accuracy: While not explicitly stated as a single overall accuracy figure for the AI in this specific cohort, the study implies improved performance over radiologists in detecting MCBC. The paper does present a comparative detection rate chart showing MRI at 90%, US at 80%, AI at 70%, and MG (radiologist) at 50%.

Limitations and Future Work

The authors acknowledge several limitations:

  • Retrospective and Single-Center: The study was retrospective and conducted at a single institution, limiting generalizability.
  • Small Sample Size: The study included only 10 patients, which is a small sample for robust statistical conclusions.
  • AI Approval Status: The FxMammo™ system is not yet approved for clinical use in Japan, limiting its current application.
  • Potential AI Bias: The AI system was developed with a focus on Asian women, and its performance might vary across different demographics.

Future work suggested includes:

  • Measuring Diagnostic Time: Quantifying the time taken by radiologists and the AI system to make diagnoses.
  • Prospective Studies: Conducting prospective studies with a larger and more diverse patient population from multiple facilities.
  • Broader Validation: Expanding validation to include non-recurrent cases to further assess the AI system's utility.
  • Addressing AI Bias: Investigating and mitigating potential biases in the AI system.

Summary updated

BibTeX
@article{adachi2024ai,
  author = {Mio Adachi and Tomoyuki Fujioka and Toshiyuki Ishiba and Miyako Nara and Sakiko Maruya and Kumiko Hayashi and Yuichi Kumaki and Emi Yamaga and Leona Katsuta and Du Hao and Mikael Hartman and Mengling Feng and Goshi Oda and Kazunori Kubota and Ukihide Tateishi},
  title = {{AI Use in Mammography for Diagnosing Metachronous Contralateral Breast Cancer}},
  journal = {J. Imaging},
  year = {2024},
  doi = {10.3390/jimaging10090211},
}
Figure