AdaptReg: Skip-level FiLM Adapter for Task-Specific Adaptation of a Frozen Registration Foundation Model

Shuyue Shi, Rong Yuan, Lin TianarXiv 2026

Foundation models are taking over medical imaging, but they often lack the "finesse" required for specific clinical tasks. In a new paper, researchers introduce AdaptReg, a clever way to tune a massive, frozen registration model so it respects the delicate geometry of cancer lesions.

TL;DR

AdaptReg uses a lightweight "adapter" branch to steer a frozen registration foundation model (uniGradICON) toward task-specific goals, like preserving the volume of prostate cancer lesions. By applying FiLM-style modulation to skip connections and using a specialized volume-preservation loss, it slashes errors in metabolic tumor metrics by over 60% while maintaining state-of-the-art alignment.

What Problem Does This Paper Address?

In prostate cancer care, doctors use longitudinal PSMA-PET/CT scans to see if a treatment is working. To do this accurately, they must "register" (align) a follow-up scan to a baseline scan.

The catch? Standard registration algorithms are designed for "generic alignment"—they try to make the whole image match as closely as possible. If a tumor has changed shape, a generic model might "squish" or "stretch" the lesion in the follow-up scan just to make the images overlap better. This creates registration artifacts.

If the algorithm artificially changes the lesion's volume, clinical metrics like Metabolic Tumor Volume (MTV) and Total Lesion Glycolysis (TLG) become useless for assessing treatment response. The researchers needed a way to keep the power of a foundation model while forcing it to "leave the lesions alone" geometrically.

Methods

The authors propose a parameter-efficient fine-tuning strategy called AdaptReg. Instead of retraining a massive model from scratch, they keep the foundation model (uniGradICON) completely frozen and attach a lightweight, trainable "adapter" branch.

Key technical components include:

  • Anatomical Conditioning: They use a frozen TotalSegmentator encoder to extract semantic anatomical features from the CT scans.
  • Skip-level FiLM Modulation: They inject FiLM (Feature-wise Linear Modulation) layers into the foundation model’s decoder skip connections. These layers apply a per-voxel scale ($\gamma$) and shift ($\beta$) to the features. Because skip connections carry high-frequency spatial details, modulating them allows the adapter to precisely "steer" the resulting displacement field.
  • Identity-Preserving Initialization: The adapter starts nearly invisible ($\gamma \approx 1, \beta \approx 0$), ensuring the model begins with the foundation model's proven baseline behavior before learning task-specific tweaks.
  • Volume-Preservation Loss ($L_{vol}$): This is the "secret sauce." The loss function calculates the Jacobian determinant of the transformation specifically within the lesion areas. If the determinant is 1, the volume is perfectly preserved. This penalizes the model for any artificial shrinking or expanding of the tumor.
Fig. 1. (a) Without AdaptReg, the foundation model is trained with similarity and regularization losses only. (b) AdaptReg adds an adapter branch (frozen encoder + trainable FiLM generator modulating the decoder skips) and a task loss (lesion volume preservation). (c) Skip-level FiLM modulation detail.

Datasets

The model was developed for the Learn2Reg 2026 PSMAReg challenge.

  • Training: 299 image pairs derived from the public PSMA-PET-CT-Lesions dataset (597 studies from LMU University Hospital Munich).
  • Validation: An official set of 20 pairs.
  • Testing: A hidden official test set of 160 pairs (80 patients) used for the final challenge ranking.

Key Insights and Ideas

  • Foundation Models Need Guardrails: Even a "foundation" model with strong zero-shot generalization can fail clinical tasks if it isn't constrained by the specific physics or biology of the problem (like volume preservation).
  • Surgical Regularization: By detaching the lesion mask in the loss function, the authors prevent a "degenerate solution" where the network might try to shrink the mask itself to minimize the loss. This ensures the gradients only affect the transformation of the space.
  • Resolution is King: The authors found that training at the native volume resolution (288x192x192) was crucial. Resampling to smaller sizes (like 175³) distorted small anatomical structures, leading to a significant drop in Dice Similarity Coefficient (DSC).

Key Results

AdaptReg demonstrated a massive leap over the standard baseline (uniGradICON + instance optimization):

  • Metric Accuracy: It reduced MTV and TLG errors by 70.9% and 67.7%, respectively, on the validation set.
  • Alignment: It improved the Dice score (DSC) by +0.05, reaching 0.7585 on validation.
  • Challenge Performance: On the hidden test set, it achieved a CT DSC of 0.816 and ranked 4th out of 16 teams in the PSMAReg evaluation.
  • Qualitative Success: As seen in the figure below, while the baseline model "severely distorts" the lesion to achieve alignment, AdaptReg preserves the lesion's shape.
Qualitative comparison showing how AdaptReg preserves lesion shape compared to the distortions caused by the generic foundation model.

Limitations and Future Work

  • PET Integration: Currently, the adapter only looks at CT features. The authors note that incorporating PET images into the conditioning branch could help localize very small lesions that have metabolic activity but no clear anatomical signature on CT.
  • Smoothness vs. Accuracy: The test set showed a higher ratio of non-diffeomorphic (folding) voxels than the validation set. Future work will focus on improving the smoothness and regularity of the deformation fields to ensure they remain physically plausible across diverse patient cohorts.

Summary updated

Abstract

Longitudinal PSMA-PET/CT registration is a key step in assessing treatment response in prostate cancer, and it requires more than generic alignment accuracy: the deformation must preserve lesion volume, so that measured changes in metabolic tumor volume (MTV) and total lesion glycolysis (TLG) reflect treatment response rather than registration artifacts. We propose AdaptReg, which adapts a frozen registration foundation model to such task-specific requirements through a lightweight trainable adapter branch with identity-preserving initialization. Keeping uniGradICON fully frozen, we apply FiLM-style per-voxel affine modulation ($γ$, $β$) to its decoder skip connections; the modulation is generated from anatomical semantic features of a frozen TotalSegmentator encoder and supervised by a lesion volume-preservation loss. On the official Codabench validation set (20 pairs), AdaptReg achieves DSC 0.7585, HD95 6.33 mm, MTV/TLG errors of 1.68%/2.11%, and 0.0022% non-diffeomorphic voxels, improving on the uniGradICON + instance optimization baseline by $+0.05$ DSC and reducing the MTV/TLG errors by 70.9%/67.7%. On the hidden official test set (160 pairs), AdaptReg achieves CT DSC 0.816, PET DSC 0.598, and MTV/TLG errors of 4.02%/3.46%, ranking fourth among 16 teams in the final PSMAReg evaluation. Code: https://github.com/shishuyue/AdaptReg
BibTeX
@misc{shi2026adaptreg,
  author = {Shuyue Shi and Rong Yuan and Lin Tian},
  title = {{AdaptReg: Skip-level FiLM Adapter for Task-Specific Adaptation of a Frozen Registration Foundation Model}},
  year = {2026},
  eprint = {2611.25761},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.25761},
}
Figure