Adaptive Deep Image Prior Enhances Ultra-Low Dose PET Imaging with NeuroEXPLORER
Abstract
The dedicated brain PET system NeuroEXPLORER (NX) with high sensitivity, resolution, and continuous head motion correction holds the potential for ultra-low dose imaging. Low injected dose, however, still results in a decreased signal to noise ratio in the reconstructed images. The small number of scans available to date from NX poses a challenge for supervised learning-based denoising methods, which require a vast amount of training data. The goal of this study is to develop an adaptive deep image prior (ADIP) based post-processing technique for individual lowdose NX PET datasets. A reconstructed low-dose image served as the target of the ADIP network and the subject attenuation map was used as the input to provide structural information. To make the network adapt to the noise level of its target, we calculated the variance of a sequence of output within a running window to automatically determine the optimal stopping iteration and avoid overfitting. For evaluation, we generated list-mode datasets with different contrasts between gray matter and white matter ($8: 1,4: 1$, and $2: 1$) based on custom made brain phantoms scanned by NX. For each contrast, the full-count data was down-sampled to simulate $10 \%, 3 \%$, and $2 \%$ of the original counts. We calculated normalized standard deviation, relative error (RE) with respect to the full-count images, and contrast recovery coefficient (CRC) in a hot gray matter region to evaluate the lowdose images before and after ADIP processing. Achieving comparable CRC to the full-count images with all contrasts, the ADIP method reduces noise by $21 \pm 3 \%, 37 \pm 3 \%$, and $46 \pm 3 \%$ for the $10 \%, 3 \%$, and $2 \%$ count images. In addition, the ADIP method introduces negligible bias with the REs before versus after processing as $-.1 \pm.1 \%,-.2 \pm .1 \%$, and $-.2 \pm .2 \%$ versus $-.8 \pm .4 \%,-2.8 \pm 1.5 \%$, and $-1.9 \pm .3 \%$ for the $10 \%, 3 \%$, and $2 \%$ count images. We conclude that the proposed ADIP technique enables individual dataset based denoising for ultra-low dose PET imaging with NX.
BibTeX
@misc{li2024adaptive,
author = {Adam Li and Paul Gravel and J.-D. Gallezot and Takuya Toyonaga and Kathryn Fontaine and Richard E. Carson and Jing Tang},
title = {{Adaptive Deep Image Prior Enhances Ultra-Low Dose PET Imaging with NeuroEXPLORER}},
year = {2024},
doi = {10.1109/nss/mic/rtsd57108.2024.10657691},
}Ask Althea to put this paper to the test.
Loading related content...