Active feedback control used in plasma vertical unstable displacement for EAST

Haihong Huang, Ye Wang, Haixin WangProceedings of the 2nd International Conference on Computer Science and Electronics Engineering (ICCSEE 2013) 2013 · DOI

Abstract

The Experimental Advanced Superconducting Tokamak (EAST) is a critical facility for fusion research. To improve magnetic confinement, EAST utilizes an elongated plasma cross-section. However, this configuration is inherently unstable in the vertical direction. Without precise control, the plasma can collide with the vacuum vessel wall, leading to discharge failure and potential machine damage. This paper describes an active feedback control system designed to stabilize these vertical displacements. By utilizing internal active feedback coils and a fast control power supply, the system successfully restrains plasma motion, as confirmed by experimental results.

The Challenge of Elongated Plasmas

In the pursuit of efficient nuclear fusion, Tokamaks like EAST aim to maximize $\beta$, the ratio of plasma pressure to magnetic energy density. Elongating the plasma's cross-section is a key strategy to achieve this. However, elongated plasmas are vertically unstable. Any small displacement from the equilibrium position is amplified by the magnetic field configuration—specifically when the field reduction factor $n < 0$—causing the plasma to drift rapidly toward the vessel walls. This "disruption" terminates the experiment and subjects the vessel to extreme thermal and mechanical stress.

Active Feedback Control Strategy

To maintain stability, EAST employs a multi-tiered approach. While the vacuum vessel walls provide passive stabilization via induced eddy currents, this effect decays too quickly to handle sustained instability. The primary defense is an active feedback system consisting of:

  1. Plasma Control System (PCS): This system monitors the plasma's vertical position ($Z_p$) and uses a Proportional-Differential (PD) controller to calculate corrective signals.
  2. Fast Control Power Supply (FCPS): A high-performance 560kVA power system utilizing a 36-phase rectification scheme. This allows for extremely fast and smooth current tracking, essential for responding to rapid plasma drifts.
  3. Internal Coils (IC1 & IC2): Because the stainless steel vacuum vessel acts as a magnetic shield—introducing delays of up to 24ms—the active feedback coils are placed inside the vessel. These coils generate a radial magnetic field that produces an immediate corrective Lorentz force on the plasma.
The layout of the EAST Tokamak, showing the elongated plasma shape and the internal control coils (IC1 and IC2) used for vertical stabilization.

System Architecture and Physics

The control loop integrates diagnostic measurements with high-speed power electronics to close the feedback loop in real-time. The diagnostic system measures the plasma's displacement and shape, feeding this data back to the main control system.

The active feedback control loop for EAST, illustrating the interaction between the plasma diagnostic system, the main control system, and the fast control power supply.

By bypassing the vessel's shielding delay through the use of internal coils, the system can react to instabilities that grow on a millisecond timescale. The FCPS ensures that the current in these coils precisely follows the commands from the PD controller, maintaining the plasma in its intended position.

Experimental Results and Conclusion

Experimental discharges on EAST have validated this control scheme. Waveform data indicates that the fast control power supply tracks the PCS commands with high fidelity, and the vertical displacement of the plasma is successfully restrained even in highly elongated configurations. This stability is a prerequisite for long-pulse, steady-state fusion experiments. Future work will involve further tuning of the control algorithms to handle the complex interactions between vertical stability and other plasma shape parameters as researchers push for even higher performance regimes.

Summary updated

Abstract

Superconducting Tokamak), a National Mage-project of Science Research of China, is a very important fusion experiment facility. The ability of magnetic confinement to plasma can be improved by elongating plasma cross-section to form divertor configuration in EAST. But elongated plasma has vertical displacement instability, without control, plasma will dash against wall of vacuum vessel and disrupt, that will cause failure of plasma discharge. So feedback control system is needed to restrain plasma vertical displacement. Fast control power supply excites active feedback coils, which produces magnetic field to control plasma's displacement. The validity of proposed scheme was confirmed by experiments, the active feedback system can reach design demand.
BibTeX
@inproceedings{huang2013active,
  author = {Haihong Huang and Ye Wang and Haixin Wang},
  title = {{Active feedback control used in plasma vertical unstable displacement for EAST}},
  booktitle = {Proceedings of the 2nd International Conference on Computer Science and Electronics Engineering (ICCSEE 2013)},
  year = {2013},
  doi = {10.2991/iccsee.2013.512},
}
Figure