Localized arc filament plasma actuators were used to control a supersonic jet from an axisymmetric nozzle of design Mach number of 1.3 operating from overexpanded to underexpanded flow regimes with the fully expanded jet Mach number (MJ) from 1.1 to 1.5. The Reynolds number based on the 2.54 cm nozzle exit diameter was from 1.0x10 6 to 1.4x10 6 . Laser based planar flow visualizations, schlieren imaging, and particle imaging velocimetry measurements were used to evaluate the effects of control. Eight actuators, distributed azimuthally approximately 1 mm upstream of the nozzle exit, were used to force various azimuthal modes over a large frequency range (StDF of 0.07 to 2.70). The preliminary results in the underexpanded jets (MJ = 1.4 and 1.5) were quite similar to our previous results in the ideally expanded jet (MJ = 1.3). The jet responded to the forcing over the entire range of frequencies, but the response was optimum (in terms of development of large coherent structures and mixing enhancement) around the jet preferred Strouhal number of 0.33 (f = 5 kHz). The jet also responded to forcing with various azimuthal modes (m=0 to 3 and m= ±1, ±2, ±4). Forcing the jet with the azimuthal mode m= ±1 at the jet preferred mode frequency provided the maximum mixing enhancement. Conversely, the preliminary results showed that the overexpanded jets (MJ = 1.1 and 1.2) did not respond at all or the response was relatively small. Detailed experiments are underway to further explore this issue.
BibTeX
@inproceedings{samimy2008active,
author = {Mo Samimy and Robert Snyder and Jin-Hwa Kim and Igor Adamovich},
title = {{Active Control of Supersonic Jets Operating in Various Flow Regimes}},
booktitle = {46th},
year = {2008},
doi = {10.2514/6.2008-631},
}Loading related content...