NeurIPS 2026Coming to NeurIPS?Explore papers, orals & directions

Abstract 4120966: Outcomes Following Balloon Angioplasty with Drug Coated Versus Uncoated Balloons in Patients with Coronary In-Stent Restenosis: A Systematic Review and Meta-Analysis

Mohammad Ebad Ur Rehman, Burhan Khalid, Muhammad Haris Khan, Muhammad Waseem, N. U. Rehman, Zain Ul Abideen, M. B. Jamil, Muhammad Hamza, Malaika Nasir, Abdullah Afridi, Shehroz Masood, Hamza Shahram, Sajeel Saeed, Tehseen Haider, Jawad Basit, Usman Akbar, Ahmad IftikharCirculation 2024

Abstract

Background <div> </div> <div>The development of in-stent restenosis (ISR) has emerged as a substantial barrier to interventional treatment for coronary heart disease. Drug-coated balloon (DCB) is an efficacious interventional technique for the management of ISR. This meta-analysis compares the efficacy of DCB in the treatment of ISR with that of an uncoated balloon (UCB).</div> <div> </div> <div>Methods</div> <div> </div> <div>We comprehensively searched literature on MEDLINE, Embase, Cochrane, and clinicaltrials.gov using MeSH terms and relevant keywords for “Balloon Angioplasty” and “in-stent Restenosis” from inception to June 1, 2024, followed by a meta-analysis of all randomized controlled trials (RCTs) to assess both strategies for treatment of ISR. Random effects model was used to aggregate the risk ratios (RR) for dichotomous and mean differences (MD) for continuous outcomes, with 95% confidence intervals (CI).</div> <div> </div> <div>Results</div> <div> </div> <div>The search strategy retrieved 2330 studies. Duplicates and irrelevant articles were removed and data from seven RCTs (1,408 patients) was extracted. The mean age ranged from 64 to 74 years. The mean clinical follow-up ranged from 1 to 10 years. DCB was found to be superior to UCB at latest follow up in terms of target lesion revascularization (TLR) (RR 0.34, 95% CI 0.19-0.58; p 0.0001; I2 79%), major adverse cardiovascular events (MACE) (RR 0.41, 95% CI 0.23-0.73; p 0.003; I2 84%), late lumen loss (LLL) (MD -0.46 mm, 95% CI -0.64- -0.28]; p <0.00001; I2 64%), and target vessel revascularization (TVR) (RR 0.45, 95% CI 0.29-0.70; p 0.0003; I2 67%). The two groups were comparable at latest follow up in terms of mortality (RR 0.87, 95% CI 0.65-1.16; p 0.35; I2 0%), cardiac death (RR 0.89, 95% CI 0.66-1.19; p 0.43; I2 0%), myocardial infarction (MI) (RR 0.70, 95% CI 0.39-1.24; p 0.22; I2 28%) and stent thrombosis (RR 0.22, 95% CI 0.04-1.10; p 0.06; I2 46%).</div> <div> </div> <div> </div> <div> </div> <div>Conclusion</div> <div> </div> <div>DCB showed promising results in the treatment of patients with coronary ISR. DCB outperformed UCB in significantly reducing TLR, MACE, LLL and TVR risks. The risk of mortality, cardiac death, MI, and stent thrombosis was similar between DCB and UCB.</div> <div> </div> <div> </div>
BibTeX
@inproceedings{rehman2024abstract,
  author = {Mohammad Ebad Ur Rehman and Burhan Khalid and Muhammad Haris Khan and Muhammad Waseem and N. U. Rehman and Zain Ul Abideen and M. B. Jamil and Muhammad Hamza and Malaika Nasir and Abdullah Afridi and Shehroz Masood and Hamza Shahram and Sajeel Saeed and Tehseen Haider and Jawad Basit and Usman Akbar and Ahmad Iftikhar},
  title = {{Abstract 4120966: Outcomes Following Balloon Angioplasty with Drug Coated Versus Uncoated Balloons in Patients with Coronary In-Stent Restenosis: A Systematic Review and Meta-Analysis}},
  booktitle = {Circulation},
  year = {2024},
  doi = {10.1161/circ.150.suppl\_1.4120966},
}

Loading related content...

Figure