NeurIPS 2026Coming to NeurIPS?Explore papers, orals & directions

Abstract 345: Direct Ultrasound-Based Quantification of Bleeding from a Junctional Femoral Artery Wound During Fluid Resuscitation

Nathan J. White, Diana Chien, Xu Wang, Esther B. Lim, Alexander E. St. John, Andrew W. Kirkpatrick, Jessica McKee, Susan A. SternCirculation 2014

Abstract

Background: Hypotensive resuscitation is a strategy to reduce blood loss after injury even though associations between blood pressure and bleeding remain poorly understood. We used ultrasound to quantify bleeding during fluid resuscitation in a pilot study using a swine bleeding model. We hypothesized that bleeding is associated with central hemodynamics and clot formation during fluid resuscitation. Methods: Immature swine (N=8) were anesthetized and hemorrhagic shock was induced by bleeding from a 5mm femoral arteriotomy. A wound sealing device (iTClamp™) was applied to the wound, sealing the skin. A 15ml/kg bolus of 6% hydroxyethyl starch solution was infused followed by Lactated Ringers to maintain mean arterial pressure (MAP)=60mmHg for up to 3 hours. Hemodynamic and thrombelastographic (TEG) measurements were made. Bleeding was measured using Doppler ultrasound to identify a pulsatile jet of blood within the wound hematoma and mean wound bleeding velocity (WBV) in cm/sec was calculated. Results: Survival was 50% (4/8), and mean blood loss was 34ml/kg in survivors vs. 44ml/kg in nonsurvivors (T test, p<0.001). WBV was significantly and positively associated with MAP (R=0.34, p=0.016) and cardiac output (R=0.43, p=0.002) and WBV tended to be increased in survivors (88 cm/sec vs. nonsurvivors (72cm/sec, p=0.07). The association between MAP and WBV could be impacted by clot strength only when MAP was hypotensive (<50mmHg) (ANOVA interaction effect p=0.004). Maintenance of a contained high-velocity bleeding pocket within a clot-based pseudo aneurysm was seen as a possible mechanism governing the associations between MAP, clot strength, and WBV. Conclusion: This pilot study supports a hypotensive resuscitation strategy to reduce junctional arterial bleeding. Normotensive conditions may reduce the effects of clot-enhancing hemostatic therapy during fluid resuscitation of uncontrolled hemorrhage. ![][1] [1]: /embed/graphic-1.gif
BibTeX
@inproceedings{white2014abstract,
  author = {Nathan J. White and Diana Chien and Xu Wang and Esther B. Lim and Alexander E. St. John and Andrew W. Kirkpatrick and Jessica McKee and Susan A. Stern},
  title = {{Abstract 345: Direct Ultrasound-Based Quantification of Bleeding from a Junctional Femoral Artery Wound During Fluid Resuscitation}},
  booktitle = {Circulation},
  year = {2014},
}

Loading related content...

Figure