Absolute Measurement of the Refractive Index of Water by a Mode-Locked Laser at 518 nm

Zhaopeng Meng, Xiaoyu Zhai, Jianguo Wei, Zhiyang Wang, Hanzhong WuSensors 2018 · OpenReview

TL;DR

This paper presents a novel method for precisely measuring the refractive index of water using a frequency comb and a modified Michelson interferometer. By placing the interferometer within a water-filled container and scanning a mirror, the system achieves an unprecedented measurement uncertainty of $10^{-5}$, crucial for underwater optical applications.

What Problem Does This Paper Address?

Underwater optical communication and sensing technologies are gaining traction due to their advantages over acoustic methods, such as higher bandwidth and resolution. However, a critical challenge for these optical systems is accurately accounting for the refractive index of water, which varies with wavelength, temperature, and density. Traditional methods for measuring the refractive index of liquids, like refractometry and interferometry, often suffer from complexity, limited accuracy (around $10^{-4}$), or require precise knowledge of container dimensions and thermal compensation. This paper aims to overcome these limitations by developing a more accurate and simpler method for absolute refractive index measurement of water.

Methods

The core of the proposed method is a frequency comb-based interferometric system. A mode-locked laser emitting at 518 nm is split into two paths: one directed through a Michelson interferometer and the other used for scanning. The entire Michelson interferometer, including both reference and measurement mirrors, is submerged in a quartz-glass container filled with water. This design ingeniously cancels out the need for thermal expansion compensation of the container, as both paths experience the same thermal fluctuations.

A scanning mirror in the second path is moved, generating cross-correlation patterns between the two beams. By analyzing these patterns, the system can determine the optical path lengths with and without water. Specifically, the length in air ($L_a$) is measured first, and then the length in water ($L_{gw}$ for group refractive index, $L_p$ for phase refractive index) is measured. The refractive index is then calculated by comparing these lengths and accounting for the refractive index of air. A fringe counting interferometer using a continuous-wave laser is employed to precisely track the scanning mirror's position.

Datasets

Not discussed in the paper.

Key Insights and Ideas

  • Self-Compensating Interferometer: Placing the entire interferometer within the water container is a clever way to eliminate the need for separate thermal compensation of the container itself, simplifying the setup and reducing error sources.
  • Frequency Comb Precision: The use of a frequency comb, known for its high accuracy and precision, is leveraged to achieve a measurement uncertainty an order of magnitude better than traditional methods.
  • Absolute Measurement: The method allows for absolute measurement of the refractive index, meaning it doesn't rely on pre-existing calibration standards for the water itself.
  • Dispersion Significance: The study highlights the significant dispersion of water in the visible spectrum, showing that the pulse broadens considerably due to water's frequency-dependent refractive index.

Key Results

The experimental results demonstrate a high degree of accuracy for the refractive index measurement of water.

  • Group Refractive Index: The measured group refractive index of water at 518 nm was found to be 1.36621, showing a difference of only $1 \times 10^{-5}$ compared to values calculated by the empirical Harvey formula.
  • Phase Refractive Index: Measurements across a spectral range of 515 nm to 521 nm showed a difference of less than $1 \times 10^{-5}$ between the proposed method and the empirical formula. The water dispersion was found to be significant, around $2.5 \times 10^{-4}$ over this 6-nm range.
  • Long-Term Stability: Long-term experiments over a 5-hour period showed measurement uncertainties well below $2 \times 10^{-5}$ for the group refractive index and $1.2 \times 10^{-5}$ for the phase refractive index.

Limitations and Future Work

The authors acknowledge that the entire system is currently relatively expensive due to the cost of the frequency comb. They suggest that the development of a portable and low-cost frequency comb would be a significant advancement for broader adoption of this technology in marine applications. Future work could focus on miniaturizing the system and exploring its application in more complex underwater environments.

Summary updated

Abstract

In this paper, we demonstrate a method using a frequency comb, which can precisely measure the refractive index of water. We have developed a simple system, in which a Michelson interferometer is placed into a quartz-glass container with a low expansion coefficient, and for which compensation of the thermal expansion of the water container is not required. By scanning a mirror on a moving stage, a pair of cross-correlation patterns can be generated. We can obtain the length information via these cross-correlation patterns, with or without water in the container. The refractive index of water can be measured by the resulting lengths. Long-term experimental results show that our method can measure the refractive index of water with a high degree of accuracy—measurement uncertainty at 10−5 level has been achieved, compared with the values calculated by the empirical formula.
BibTeX
@inproceedings{meng2018absolute,
  author = {Zhaopeng Meng and Xiaoyu Zhai and Jianguo Wei and Zhiyang Wang and Hanzhong Wu},
  title = {{Absolute Measurement of the Refractive Index of Water by a Mode-Locked Laser at 518 nm}},
  booktitle = {Sensors},
  year = {2018},
  url = {https://openreview.net/forum?id=i3Oz2XS19Q},
}
Figure