A Wide Measurement Range and Fast Update Rate Integrated Interface for Capacitive Sensors Array
Lists
Only you see this
Abstract
A CMOS Capacitance-to-Digital Converter (CDC) for capacitive sensors array applications is presented. It consists of a 16:1 multiplexer, a capacitance-to-voltage front-end and a 16-bit voltage-to-pulses converter. The proposed capacitance-to-voltage front-end circuit extends the dynamic range by charging or discharging the measured capacitive sensors indirectly. For low power consumption and short conversion time, hardware reuse technique and multi-steps quantization method have been applied in voltage-to-digital pulse converter design. This 16-ch CDC's maximum absolute input capacitance is 350 pF under a non-uniform distributed sampling interval of 0.15-0.75 ms with 90 μA current consumption under ±0.9 V voltage supply. This prototype chip has been designed and fabricated in 0.18- μm 1P6M CMOS process with active area of 640 × 630 μm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> .
BibTeX
@article{zhang2014wide,
author = {Xu Zhang and Ming Liu and Bo Wang and Hong Chen and Zhihua Wang},
title = {{A Wide Measurement Range and Fast Update Rate Integrated Interface for Capacitive Sensors Array}},
journal = {IEEE Trans. Circuits Syst. I Regul. Pap.},
year = {2014},
url = {https://openreview.net/forum?id=diVMeUYGMx},
}Loading related content...