A universal translator for AI scores: Providing context using error

Maggie Chung, Michael H. Bernstein, Adam Yala, Grayson L. BairdmedRxiv 2025

TL;DR

Radiology AI models often output arbitrary numeric scores (e.g., 0.0 to 1.0) that lack intrinsic meaning and vary across different software vendors. This paper proposes a "universal translator" framework that uses local disease prevalence to convert these scores into actionable metrics—False Discovery Rate (FDR) and False Omission Rate (FOR)—allowing clinicians to understand the actual probability of disease at any given threshold.

What Problem Does This Paper Address?

In modern radiology, AI tools act as "second readers," flagging potential pathologies with a numeric risk score. However, these scores suffer from three major "interpretability gaps":

  1. Lack of Intrinsic Meaning: What does a score of 0.70 actually represent? Without context, it’s unclear if that indicates a 7% or a 70% chance of cancer.
  2. Proprietary Inconsistency: A 0.90 from "Vendor A" might represent a completely different risk level than a 0.90 from "Vendor B."
  3. Non-Linearity: The jump in risk from a score of 0.2 to 0.3 is rarely the same as the jump from 0.6 to 0.7.

Because radiologists only see the score—not the ground truth—traditional metrics like sensitivity and specificity (which require knowing the ground truth beforehand) are unhelpful for real-time decision-making.

Methods

The authors propose providing radiologists with the False Discovery Rate (FDR) and False Omission Rate (FOR) for every possible score threshold.

  • FDR (1 - Positive Predictive Value): The probability that a case flagged at or above a certain score is actually negative.
  • FOR (1 - Negative Predictive Value): The probability that a case below a certain score is actually positive (a "miss").

To demonstrate this, they used Mirai, an open-source AI model for breast cancer risk. They outlined two ways for a hospital to calculate these "translator" values:

  • Local Validation: Regressing historical outcomes against AI scores using generalized linear models.
  • Bayesian Estimation: If historical data isn't available, clinicians can use their local disease prevalence combined with the AI’s published sensitivity/specificity to estimate FDR and FOR via Bayes’ Theorem.

Datasets

The study utilized a massive retrospective dataset from the University of California, San Francisco (UCSF):

  • Size: 130,712 digital screening mammograms.
  • Timeline: Acquired between January 2006 and January 2023.
  • Composition: 907 positive exams (biopsy-proven cancer within 12 months) and 129,805 negative exams (at least 12 months of cancer-free follow-up).
  • Base Rate: The local cancer prevalence was 0.69%.

Key Insights and Ideas

  • The "Accuracy Paradox" in High Scores: Even at the highest end of the AI's scoring range (0.90), the predicted probability of cancer was only about 21.5%. This means that even for the "scariest" scores, more than half of the cases (FDR of 56%) are actually negative.
  • Non-Uniform Risk Scaling: The researchers found that a 0.10 increase in score at the low end (0.20 to 0.30) only increased the probability of cancer by 0.36%. However, the same 0.10 increase at the higher end (0.60 to 0.70) nearly doubled the risk (a 3.4% increase).
  • Context is Local: The paper emphasizes that AI scores are not "set it and forget it." Because FDR and FOR depend heavily on disease prevalence, the same AI score means something different in a high-risk diagnostic clinic than it does in a general screening population.

Key Results

Using the UCSF data and the Mirai model, the "translator" revealed:

  • At a score of 0.50: The probability of cancer is 2.62%. The FDR is 95% (95 out of 100 cases at this score are false alarms), and the FOR is 0.2% (only 2 in 1,000 cases below this score are missed cancers).
  • At a score of 0.01 (Low end): FDR was 99.27% and FOR was 0.03%.
  • At a score of 0.90 (High end): FDR dropped to 56% and FOR rose to 0.7%.
  • Clinical Utility: By converting these to "number of patients," the authors showed that for every 1,000 mammograms, a score threshold of 0.50 would result in 54 false positives and 4 false negatives.

Limitations and Future Work

  • Data Requirements: The most accurate version of this "translator" requires hospitals to have high-quality historical data to perform local validation.
  • Population Shifts: If the patient population changes (e.g., a new high-risk screening program is implemented), the FDR/FOR tables must be recalculated to remain accurate.
  • Human Factors: While the paper provides the mathematical framework, it does not yet test whether providing these error rates actually improves radiologist performance or reduces "automation bias" in a clinical setting. Future work should investigate how clinicians integrate these probabilities into their workflow.