NeurIPS 2026Coming to NeurIPS?Explore papers, orals & directions

A time-frequency domain approach of heart rate estimation from photoplethysmographic (PPG) signal

Mohammad Tariqul Islam, Ishmam Zabir, Sk. Tanvir Ahamed, Md. Tahmid Yasar, Celia Shahnaz, Shaikh Anowarul FattahBiomedical Signal Processing and Control 2017

TL;DR

This paper presents a novel method for accurately estimating heart rate from wrist-worn photoplethysmography (PPG) signals, even during intense physical activity. By combining multi-stage adaptive filtering in the time domain with Singular Spectrum Analysis (SSA) in the frequency domain, the approach effectively mitigates motion artifacts, leading to significantly improved accuracy and smoother heart rate tracking compared to existing methods.

What Problem Does This Paper Address?

Wearable devices are increasingly used for continuous heart rate monitoring using photoplethysmography (PPG) signals due to their simplicity and low cost. However, a major challenge in this application is the corruption of PPG signals by motion artifacts, especially during physical activities like walking or running. These artifacts can significantly distort the PPG signal, making it difficult to accurately extract the underlying heart rate. Existing methods often struggle to effectively remove these artifacts, leading to inaccurate estimations and unreliable tracking, particularly when motion is dynamic and unpredictable.

Methods

The proposed method employs a two-pronged approach, integrating both time and frequency domain techniques for robust motion artifact reduction.

  • Multi-stage Cascaded RLS Filtering (Time Domain): Instead of a single adaptive filter, the authors propose a cascaded three-stage Recursive Least Squares (RLS) adaptive filtering architecture. Crucially, each stage uses one of the three accelerometer channels (X, Y, and Z) as a reference signal. This sequential processing allows for a more comprehensive removal of motion artifacts by leveraging the distinct motion patterns captured by each accelerometer axis.
  • Singular Spectrum Analysis (SSA) (Frequency Domain): SSA is used as a complementary technique to further reduce noise and motion artifacts. It decomposes the PPG signal into components, allowing for the identification and suppression of those associated with motion.
  • Logical Combination: The outputs from the RLS filtering and SSA stages are not simply added. A conditional combination strategy is employed. If the SSA-processed signal's dominant frequency is close to the previously estimated heart rate, the SSA output is added to the RLS output to enhance the true heart rate peak. Otherwise, only the RLS-filtered signal is used, preventing false positives from strong motion artifact peaks.
  • Heart Rate Tracking: A robust tracking algorithm is implemented. It uses the previous heart rate estimate to define a search region for the current window, preventing drastic jumps. A three-point moving average is used for smoothing, and a final verification step ensures that the estimated heart rate remains within a reasonable range of the previous estimate.

Datasets

The performance of the proposed method was evaluated using a publicly available PPG dataset. This dataset includes:

  • Two-channel PPG signals.
  • Three-axis accelerometer data.
  • Ground truth heart rate values in BPM. The data was collected from 12 male subjects performing physical activities (walking/running on a treadmill) for 5 minutes each, with a sampling rate of 125 Hz.

Key Insights and Ideas

  • Leveraging Multi-axis Accelerometer Data: The key insight is that using each accelerometer axis sequentially as a reference in a cascaded RLS filter is more effective than using a single reference or an average of all axes. This allows the filter to adapt to different motion artifact characteristics captured by each sensor.
  • Synergy of Time and Frequency Domain: Combining time-domain RLS filtering with frequency-domain SSA provides a more comprehensive artifact removal strategy. RLS excels at adaptive noise cancellation based on reference signals, while SSA can identify and suppress spectral components related to noise and artifacts.
  • Conditional Combination for Robustness: The conditional combination of RLS and SSA outputs is critical. It prevents the method from being misled by strong artifact peaks that might remain after SSA processing, especially when they don't align with the expected heart rate.
  • Importance of Tracking: A sophisticated tracking mechanism, incorporating a search region based on previous estimates and smoothing, is essential for maintaining a continuous and accurate heart rate reading, even when the raw signal is noisy.

Key Results

  • Low Estimation Error: The proposed method achieved an average absolute error of 1.16 BPM with a standard deviation of 1.74 BPM across all subjects. This is significantly lower than other state-of-the-art methods like TROIKA, JOSS, and SPECTRAP.
  • Superior Performance: In comparisons, the proposed method consistently outperformed other methods in terms of Average Absolute Error (AAE) and standard deviation, particularly when considering all time frames without exclusion.
  • Accurate Tracking: The heart rate tracking capability was demonstrated to be superior, closely following the ground truth even during abrupt changes in heart rate, as shown in performance comparisons for subjects 2 and 4.
  • Computational Feasibility: The average computational time per time window was 170 ms on a standard processor, making it feasible for implementation in wearable devices.

Limitations and Future Work

  • Limitations:
    • While the RLS-based approach is robust, the paper notes that in some cases, complete removal of motion artifacts might not be achieved, especially when the spectral characteristics of artifacts differ significantly from accelerometer signals.
  • The conditional combination strategy relies on the accuracy of the previous heart rate estimate to define the search range for the current window. If the previous estimate is significantly erroneous, it could impact the current estimation.
  • Future Work:
    • The authors suggest that further exploration of spectral domain techniques, potentially beyond SSA, could lead to even better motion artifact removal.
  • Optimization of the code is mentioned as a possibility to further reduce computational time, enhancing its suitability for real-time applications on resource-constrained wearable devices.
  • Investigating the use of LMS filters as an alternative to RLS (as explored in case C-3) could offer a trade-off between accuracy and computational cost.

Summary updated

BibTeX
@article{islam2017time,
  author = {Mohammad Tariqul Islam and Ishmam Zabir and Sk. Tanvir Ahamed and Md. Tahmid Yasar and Celia Shahnaz and Shaikh Anowarul Fattah},
  title = {{A time-frequency domain approach of heart rate estimation from photoplethysmographic (PPG) signal}},
  journal = {Biomedical Signal Processing and Control},
  year = {2017},
  doi = {10.1016/j.bspc.2017.03.020},
}
Figure