A thundercloud electric field sounding: Charge distribution and lightning
Abstract
An instrumented free balloon measured electric fields and field changes as it rose through a thundercloud above Langmuir Laboratory, New Mexico. The variation of the electric field with altitude implied that the cloud contained negative space charge of density −0.6 to −4 nC m −3 between 5.5 and 8.0 km MSL. The environmental temperature at these levels ranged from −5° to −20°C. Our measurements imply that the areal extent of this negative charge center was significantly greater than that of the cloud's intense precipitation shafts. At altitudes greater than 8 km, the instrument ascended past net positive charge. We also inferred from our measurements positive space charge adjacent to the earth's surface (concentration 0.6 nC m −3 ) and in the lowest portion of the cloud (1.0 nC m −3 ). Electric field changes from intracloud lightning were interpreted by using a simple model for the developing streamer of the initial phase. Thunder source reconstructions provided estimates for the orientation of lightning channels. Seven ‘streamers’ so analyzed propagated on the average, at 5×10 4 m s −1 and carried a current of 390 A. The mean charge dissipated during a flash was 30 C.
BibTeX
@article{weber1982thundercloud,
author = {Mark Weber and H. J. Christian and A. A. Few and M. F. Stewart},
title = {{A thundercloud electric field sounding: Charge distribution and lightning}},
journal = {Journal of Geophysical Research Atmospheres},
year = {1982},
doi = {10.1029/jc087ic09p07158},
}Ask Althea to put this paper to the test.
Loading related content...