A telescopic microscope equipped with a quanta image sensor for live-cell bioluminescence imaging

Ruixin Ma, Luciano M. Santino, Tomáš Chobola, Niklas Armbrust, Julian Geilenkeuser, S. Sukumaran, Zhizi Jing, Anastasia Levkina, Korneel Ridderbeek, Tingying Peng, Dong‐Jiunn Jeffery Truong, Sebastian Doll, Gil G. Westmeyer, Jian CuiNature Methods 2025 · DOI

TL;DR

Bioluminescence imaging, a powerful tool for observing biological processes without the drawbacks of fluorescence, has been limited by low light intensity. This paper introduces a novel microscope design, the "QIScope," that leverages a new Quanta Image Sensor (QIS) technology to overcome these limitations, enabling unprecedented detail and scope in live-cell bioluminescence studies.

What Problem Does This Paper Address?

Live-cell imaging is crucial for understanding biological processes, and while fluorescence microscopy is widely used, it suffers from issues like phototoxicity, photobleaching, and limited dynamic range. Bioluminescence offers an attractive alternative, generating its own light and avoiding these problems. However, bioluminescence is inherently weak, making it difficult to capture detailed images. Existing high-sensitivity cameras, like EMCCDs, have limitations in spatial resolution, field of view (FOV), and dynamic range when used in bioluminescence microscopy. This paper tackles the challenge of achieving high-quality bioluminescence imaging by combining a new, highly sensitive camera technology (QIS) with an innovative microscope design.

Methods

The core innovation is a "QIScope," a microscope built around a commercial Quanta Image Sensor (QIS) camera. To maximize the QIS's potential, especially its small sensor size, the authors designed a Keplerian telescope-inspired optical setup. This design effectively "shrinks" the image onto the sensor, increasing photon flux per pixel while maintaining a large FOV. This is a departure from traditional microscope designs that often sacrifice FOV for resolution or sensitivity. The QIScope also allows for easy integration of epifluorescence imaging, enabling multimodal experiments. The authors benchmarked their QIScope against a state-of-the-art commercial bioluminescence microscope (Olympus LV200 with an EMCCD) and other high-sensitivity cameras (sCMOS and EMCCD) using fluorescent slides, quantum dot-labeled cells, and live-cell bioluminescence experiments.

Datasets

The study utilized several cell lines for imaging:

  • Mouse embryonic fibroblasts (MEFs) labeled with quantum dots for camera benchmarking.
  • EXSISERS cells for imaging weak live-cell bioluminescence.
  • MEFs expressing NLuc fused to CD63 (an exosomal marker) to study extracellular vesicles (EVs).
  • MEFs expressing NLuc targeted to different subcellular locations (cytoplasm, plasma membrane, exosomes/MVBs) to analyze EV dynamics.
  • HEK293T cells expressing Gamillus-NLuc and PINK1-HiBiT/LgBiT for comparing fluorescence and bioluminescence sensitivity, phototoxicity, and long-duration imaging of low-abundance proteins.

No new benchmarks were introduced; instead, the study focused on comparing the performance of the QIScope against existing systems.

Key Insights and Ideas

  • QIS cameras are game-changers for low-light imaging: The QIS camera demonstrated significantly higher signal-to-noise ratios (SNRs) compared to both sCMOS and EMCCD cameras, even under similar photon-per-pixel conditions.
  • Microscope design is critical for sensor optimization: The small sensor size of QIS cameras necessitates a rethinking of microscope optics. A simple Keplerian telescope-inspired design proved highly effective in overcoming the sensor's limitations.
  • Bioluminescence is poised for a comeback: The QIScope makes bioluminescence a much more viable and powerful tool for technically demanding live-cell experiments, especially those involving low-abundance proteins or subtle extracellular events.
  • Multimodal imaging is seamlessly integrated: The QIScope's design allows for easy switching between bioluminescence and epifluorescence, opening doors for correlative studies.
  • Bioluminescence offers superior photostability and low toxicity: Compared to fluorescence, bioluminescence imaging caused significantly less photobleaching and phototoxicity, enabling longer observation periods without harming cells.

Key Results

  • The QIScope achieved modestly improved SNR compared to the state-of-the-art LV200/EMCCD microscope.
  • Crucially, the QIScope delivered substantially higher spatial resolution, field of view (FOV), and dynamic range. Specifically, the FOV was ~3.6-fold larger, and the image resolution was 1.77 times higher than the LV200/EMCCD.
  • The QIScope successfully resolved intracellular and extracellular vesicles simultaneously, a feat difficult with previous bioluminescence setups.
  • It enabled the tracking of individual extracellular vesicles and revealed details of their diffusion dynamics.
  • The system demonstrated superior photostability and low toxicity compared to fluorescence imaging, allowing for over 18 hours of continuous imaging.
  • The dynamic range of the QIScope was nearly 4.5 times greater than the LV200/EMCCD.

Limitations and Future Work

  • Dark current noise: The authors note that the QIS camera appears to underperform at very long integration times, possibly due to dark current accumulation.
  • Wavelength optimization: The current QIScope is optimized for blue-light detection, but future work could explore adapting it for other bioluminescent reporter wavelengths.
  • Brighter substrates: The use of brighter luciferase substrates could further boost SNR and allow for even greater spatial resolution or sensitivity.
  • Integration of other modalities: The open telescopic design of the QIScope offers potential for integrating other imaging techniques like phase contrast or differential interference contrast.
  • Next-generation QIS cameras: The system could be further enhanced with future iterations of QIS technology.

Summary updated

Abstract

Bioluminescence is an attractive alternative to fluorescence for live-cell imaging; however, its low intensity has prevented widespread adoption. Specialized microscopes compensate by sacrificing spatial resolution, field of view and dynamic range-constraints imposed by the highest-sensitivity camera to date: the electron-multiplying charge-coupled device. Recently, quanta image sensor (QIS) technology has emerged for low-light imaging. Here, we show that a commercial QIS camera has exceptional sensitivity; however, its sensor dimensions necessitate a microscope designed to maximize its properties. We introduce a Keplerian-telescope-inspired microscope setup that, with the QIS, results in modestly improved signal-to-noise ratios at substantially higher spatial resolution, field of view and dynamic range, relative to the state of the art. The telescopic design also confers modularity, enabling multimodal imaging with epifluorescence. The 'QIScope' makes bioluminescence a viable tool for technically challenging live-cell experiments such as monitoring intracellular and extracellular vesicles simultaneously and the dynamics of low-abundance proteins.
BibTeX
@inproceedings{ma2025telescopic,
  author = {Ruixin Ma and Luciano M. Santino and Tomáš Chobola and Niklas Armbrust and Julian Geilenkeuser and S. Sukumaran and Zhizi Jing and Anastasia Levkina and Korneel Ridderbeek and Tingying Peng and Dong‐Jiunn Jeffery Truong and Sebastian Doll and Gil G. Westmeyer and Jian Cui},
  title = {{A telescopic microscope equipped with a quanta image sensor for live-cell bioluminescence imaging}},
  booktitle = {Nature Methods},
  year = {2025},
  doi = {10.1038/s41592-025-02694-3},
}
Figure