Abstract
The extension of an existing two-dimensional standardized power Doppler measurement into 3D three-dimensional by using an image-processing technique was shown in an in utero placental study. Three-dimensional FMBV fractional moving blood volume and VFI vascularization flow index produced significantly different results. FMBV fractional moving blood volume performed better than VFI vascularization flow index in repeatability studies. Further studies are needed to assess accuracy against a reference standard.