NeurIPS 2026Coming to NeurIPS?Explore papers, orals & directions

A Systematic Review on Integrating Artificial Intelligence for Enhanced Fault Detection in Power Transmission Systems: A Smart Grid Approach

Nijat Taghizad, Píetro LióComputing&AI 2024

Abstract

Modern electrical systems rely on sensors and relays for fault detection in three-phase transmission lines and distribution transformers, but these devices often face time complexity issues and false alarms. This study compares fault detection accuracy in models from 2023 and 2024 following PRISMA guidelines. The objectives were to identify fault types, utilize machine learning models to assess their predictive efficacy, and establish accuracy levels. A systematic literature review was performed based on AI accuracy in fault detection from scholarly articles published in reputable journals. The Novel Glass Box-Based Model was ranked as the most accurate (99%), followed by CNN (98%), GRU (92%), Random Forest (90%), Logistic Regression (74%), and Support Vector Classifier (63%). The findings suggest that AI developers should aim for 99% accuracy to meet industry requirements for smart grid reliability.

Introduction

Power grids are the lifeblood of modern society, yet they remain vulnerable to faults caused by insulation failure, natural disasters, and equipment aging. Traditionally, utilities have relied on hardware sensors and relays to detect these issues. However, these legacy systems often struggle with high time complexity and significant rates of false alarms. Such inefficiencies can lead to unnecessary power outages or catastrophic equipment failure if a critical fault is missed. As the industry transitions toward "Smart Grids," there is an urgent need for software-based detection that is both faster and more accurate than traditional methods.

Methodology

This research employed a systematic literature review following the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. The study targeted high-quality research published between 2023 and 2024 to capture the current state-of-the-art in AI-driven fault detection.

The evaluated models were categorized into two primary groups:

  1. Traditional Machine Learning Models: Logistic Regression (LR), Random Forest (RF), and Support Vector Classifiers (SVC).
  2. Modern Deep Learning and Explainable Models: Convolutional Neural Networks (CNN), Gated Recurrent Units (GRU), and a Novel Glass Box-Based Model utilizing an Explainable Boosting (EB) approach.

To ensure robustness, the researchers used the Robvis method to assess the risk of bias and Cronbach’s alpha to verify the reliability of the data synthesis.

Data Sources and Analysis

The review analyzed results derived from three primary data types:

  • Simulated Data: Generated using MATLAB/Simulink to model various fault scenarios (e.g., Line-to-Ground, Line-to-Line) under controlled conditions.
  • Public Benchmarks: Standardized datasets used to compare algorithm performance across the research community.
  • Real-World Data: Historical data from distribution transformers and transmission lines, including phase voltage, current, and oil temperature indicators.

Results and Discussion

The comparative analysis revealed a clear performance hierarchy among the models. The Novel Glass Box-Based Model (EB) achieved the highest accuracy at 99%, followed closely by Convolutional Neural Networks (CNN) at 98%. In contrast, traditional models like Logistic Regression (74%) and Support Vector Classifiers (63%) performed significantly worse, failing to capture the complex, non-linear relationships inherent in electrical signal data.

The 99% Accuracy Benchmark

A key insight from this study is that for AI to be industry-ready for power systems, it should target a minimum of 99% accuracy. Given the critical nature of grid stability, lower accuracy levels introduce unacceptable risks.

The Importance of Explainability

The success of the "Glass Box" model is particularly significant. In critical infrastructure management, engineers require transparency. Unlike "Black Box" deep learning models, Glass Box models (Explainable Boosting) allow operators to understand why a specific fault was flagged, facilitating faster and more confident decision-making.

Conclusion and Future Work

While the study highlights the superiority of modern AI approaches, it is limited by the small number of primary studies (two) that met the strict inclusion criteria. This suggests a need for more standardized reporting protocols in the field.

Future Research Directions: * Edge Deployment: Investigating how 99%-accurate models perform on limited-resource hardware, such as field relays. * Hybrid Architectures: Exploring the potential of combining deep learning's predictive power with the transparency of explainable AI. * Expanded Sourcing: Broadening future reviews to include a wider variety of hybrid models and longer timeframes.

Summary updated

BibTeX
@inproceedings{taghizad2024systematic,
  author = {Nijat Taghizad and Píetro Lió},
  title = {{A Systematic Review on Integrating Artificial Intelligence for Enhanced Fault Detection in Power Transmission Systems: A Smart Grid Approach}},
  booktitle = {Computing\&AI},
  year = {2024},
  doi = {10.69709/caic.2024.103229},
}
Figure