A Stimuli-Responsive Biosensor of Glucose on Layer-by-Layer Films Assembled through Specific Lectin-Glycoenzyme Recognition

Huiqin Yao, Qianqian Gan, Juan Peng, Shan Huang, Meilin Zhu, Keren ShiSensors 2016 · DOI

TL;DR

This paper presents a novel pH-responsive biosensor for glucose detection. By assembling layers of concanavalin A (Con A) and glucose oxidase (GOD) using specific biomolecular recognition, they created a film that can switch its electrochemical activity "on" or "off" based on the surrounding pH. This allows for controlled electrocatalytic oxidation of glucose, paving the way for more intelligent biosensing devices.

What Problem Does This Paper Address?

Developing intelligent biosensors that can dynamically control their activity based on external signals is a significant challenge. Traditional biosensors often have fixed activity, making it difficult to achieve on-demand control or complex bioelectronic functions. Specifically, while pH-responsive bioelectrocatalysis has been explored, many approaches rely on enzymes dissolved in solution, which are not easily reusable. Immobilizing enzymes is crucial for stability and efficiency, but achieving controlled, stimuli-responsive immobilization that doesn't compromise activity is difficult. This paper addresses the need for a stable, stimuli-responsive biosensor platform that leverages specific biomolecular interactions for enzyme immobilization and activity control.

Methods

The core of this work is the layer-by-layer (LbL) assembly technique. This method involves sequentially depositing alternating layers of oppositely charged materials onto a substrate. Here, the researchers utilized a biospecific recognition strategy, specifically the interaction between the lectin concanavalin A (Con A) and the glycoenzyme glucose oxidase (GOD). Con A has a known affinity for sugar residues, and GOD, being a glycoenzyme, possesses such residues on its surface. This specific interaction, rather than just electrostatic attraction, was the primary driving force for building the {Con A/GOD}n multilayer films.

Key techniques employed include:

  • Cyclic Voltammetry (CV): Used to study the electrochemical behavior of electroactive probes (like ferrocenedicarboxylic acid, Fc(COOH)₂) and to assess the bioelectrocatalytic activity of GOD.
  • Quartz Crystal Microbalance (QCM): Used to confirm the successful assembly of LbL films by monitoring mass changes during each deposition step.
  • Scanning Electron Microscopy (SEM): Used to visualize the surface morphology of the assembled films.
  • Electrochemical Impedance Spectroscopy (EIS): Used to probe the charge transfer resistance and assess the film's response to pH changes.

The pH-responsive behavior was investigated by systematically changing the pH of the buffer solutions and observing the electrochemical signals.

Datasets

Not discussed in the paper. The study focuses on the fabrication and characterization of a biosensor platform using specific biomolecules and electroactive probes.

Key Insights and Ideas

  • Biospecific Recognition as a Primary LbL Driving Force: The study highlights that using specific biomolecular interactions (lectin-glycoenzyme affinity) as the main driving force for LbL assembly can lead to more stable and controllable films compared to purely electrostatic interactions. This is because the specific binding is stronger and less susceptible to disruption by minor pH fluctuations.
  • pH-Tunable "On-Off" Switch for Bioelectrocatalysis: The {Con A/GOD}n films exhibit a remarkable pH-dependent "on-off" switching behavior for the electroactive probe Fc(COOH)₂. At acidic pH (4.0), the probe's electrochemical signal is strong ("on"), while at alkaline pH (8.0), it is significantly suppressed ("off"). This switch is reversible and can be cycled multiple times.
  • Electrostatic Interaction as the Mechanism for pH Sensitivity: While the film assembly is driven by biospecific recognition, the pH-responsive switching is attributed to changes in the electrostatic interactions between the charged probe (Fc(COOH)₂) and the charged film layers. At different pH values, the net charge of Con A and GOD changes, leading to attraction or repulsion of the probe.
  • Mediated Glucose Oxidation: The pH-controlled "on-off" state of the films can be used to modulate the bioelectrocatalytic oxidation of glucose. When the film is "on" (pH 4.0), glucose oxidation mediated by GOD and Fc(COOH)₂ is observed. When the film is "off" (pH 8.0), this catalytic activity is suppressed, demonstrating a functional application of the stimuli-responsive interface.
  • Mimicking Biological Environments: The study demonstrates the potential to achieve pH-controlled bioelectrocatalysis by using in situ enzyme-catalyzed reactions to alter the local pH, mimicking more complex biological environments.

Key Results

  • Successful LbL Assembly: QCM and CV measurements confirmed the successful and reproducible assembly of {Con A/GOD}n multilayer films.
  • Reversible pH Switching: The electrochemical response of Fc(COOH)₂ showed a significant difference between pH 4.0 (large peak currents) and pH 8.0 (suppressed peak currents), demonstrating a reversible "on-off" behavior. The response time for switching was less than 10 seconds.
  • Mechanism Confirmation: Comparative studies with probes of different charges (positively charged Ru(NH₃)₆³⁺, neutral FcMeOH, and negatively charged Fe(CN)₆³⁻) supported the conclusion that electrostatic interactions are the primary mechanism for the pH-dependent stimuli-responsive behavior.
  • Glucose Bioelectrocatalysis Control: The {Con A/GOD}₅ films enabled the activation ("on" at pH 4.0) and deactivation ("off" at pH 8.0) of glucose electrocatalytic oxidation mediated by Fc(COOH)₂.
  • Film Stability: The LbL films demonstrated good stability in pH 7.0 buffer solutions over a week and also in the presence of glucose at a concentration of 7.0 mM for 20 hours.

Limitations and Future Work

  • Film Thickness Optimization: While the study used n=5 bilayers for optimal performance, further optimization of film thickness for specific applications might be beneficial.
  • Competition with Free Glucose: The paper acknowledges that free glucose could potentially compete with GOD for binding to Con A, leading to film disintegration. However, they found that the Con A-GOD interaction is significantly stronger than Con A-glucose, and the films remained stable under the tested glucose concentrations. Further investigation into the limits of this stability at higher glucose concentrations might be warranted.
  • Broader Applications: The authors suggest that this stimuli-responsive biointerface, based on specific recognition and immobilized enzymes, provides a foundation for fabricating novel intelligent electrochemical glucose biosensors and other bioelectronic devices. Future work could explore extending this approach to other enzyme systems or for different sensing applications. The ability to mimic biological environments through in situ pH modulation also opens avenues for more complex bioelectronic systems.

Summary updated

Abstract

The research on intelligent bioelectrocatalysis based on stimuli-responsive materials or interfaces is of great significance for biosensors and other bioelectronic devices. In the present work, lectin protein concanavalin A (Con A) and glycoenzyme glucose oxidase (GOD) were assembled into {Con A/GOD}n layer-by-layer (LbL) films by taking advantage of the biospecific lectin-glycoenzyme affinity between them. These film electrodes possess stimuli-responsive properties toward electroactive probes such as ferrocenedicarboxylic acid (Fc(COOH)₂) by modulating the surrounding pH. The CV peak currents of Fc(COOH)₂ were quite large at pH 4.0 but significantly suppressed at pH 8.0, demonstrating reversible stimuli-responsive on-off behavior. The mechanism of stimuli-responsive property of the films was explored by comparative experiments and attributed to the different electrostatic interaction between the films and the probes at different pH. This stimuli-responsive films could be used to realize active/inactive electrocatalytic oxidation of glucose by GOD in the films and mediated by Fc(COOH)₂ in solution, which may establish a foundation for fabricating novel stimuli-responsive electrochemical biosensors based on bioelectrocatalysis with immobilized enzymes.
BibTeX
@inproceedings{yao2016stimuli,
  author = {Huiqin Yao and Qianqian Gan and Juan Peng and Shan Huang and Meilin Zhu and Keren Shi},
  title = {{A Stimuli-Responsive Biosensor of Glucose on Layer-by-Layer Films Assembled through Specific Lectin-Glycoenzyme Recognition}},
  booktitle = {Sensors},
  year = {2016},
  doi = {10.3390/s16040563},
}
Figure