A Spatial-Physics Informed Model for 3D Spiral Sample Scanned by SQUID Microscopy

J. Senthilnath, Jayasanker Jayabalan, Zhuoyi Lin, Aye Phyu Phyu Aung, Chen Hao, Kaixin Xu, Yeow Kheng Lim, F. C. WellstoodarXiv 2025 · OpenReview

Abstract: The development of advanced packaging is essential in the semiconductor manufacturing industry. However, non-destructive testing (NDT) of advanced packaging becomes increasingly challenging due to the depth and complexity of the layers involved. In such a scenario, Magnetic field imaging (MFI) enables the imaging of magnetic fields generated by currents. For MFI to be effective in NDT, the magnetic fields must be converted into current density. This conversion has typically relied solely on a Fast Fourier Transform (FFT) for magnetic field inversion; however, the existing approach does not consider eddy current effects or image misalignment in the test setup. In this paper, we present a spatial-physics informed model (SPIM) designed for a 3D spiral sample scanned using Superconducting QUantum Interference Device (SQUID) microscopy. The SPIM encompasses three key components: i) magnetic image enhancement by aligning all the "sharp" wire field signals to mitigate the eddy current effect using both in-phase (I-channel) and quadrature-phase (Q-channel) images; (ii) magnetic image alignment that addresses skew effects caused by any misalignment of the scanning SQUID microscope relative to the wire segments; and (iii) an inversion method for converting magnetic fields to magnetic currents by integrating the Biot-Savart Law with FFT. The results show that the SPIM improves I-channel sharpness by 0.3% and reduces Q-channel sharpness by 25%. Also, we were able to remove rotational and skew misalignments of 0.3° in a real image. Overall, SPIM highlights the potential of combining spatial analysis with physics-driven models in practical applications.

Introduction

As semiconductor packaging evolves toward complex, multi-layered 3D structures, identifying internal defects without destroying the device—known as non-destructive testing (NDT)—becomes increasingly difficult. Magnetic Field Imaging (MFI) is a powerful tool for this purpose because magnetic fields penetrate packaging materials without interference.

Superconducting QUantum Interference Device (SQUID) microscopy is among the most sensitive MFI techniques. However, its practical application is hindered by two primary factors: eddy current interference and physical misalignment. High-frequency testing induces secondary eddy currents in nearby conductive materials, blurring the primary magnetic signal. Furthermore, microscopic scanning heads are difficult to align perfectly with 3D circuits; even a 0.3-degree tilt can significantly distort current path reconstruction. Traditional inversion methods rely on simple Fast Fourier Transforms (FFT) that often ignore these physical realities.

The Spatial-Physics Informed Model (SPIM)

To address these challenges, we propose the Spatial-Physics Informed Model (SPIM), a pipeline that integrates spatial image processing with electromagnetic physics to produce high-fidelity current density maps.

The SPIM pipeline flowchart illustrating the transition from SQUID image acquisition to final current density mapping.

The SPIM operates in three distinct stages:

  1. Magnetic Image Enhancement (Phase Tuning): SQUID detectors produce In-phase (I) and Quadrature (Q) data channels. Eddy currents are phase-shifted signals that typically blur the I-channel. By using a Total Variation (TV) score to measure image sharpness, the model finds the optimal phase rotation to "push" blurry eddy current signals into the Q-channel, effectively focusing the primary I-channel image.
  2. Magnetic Image Alignment: The model employs affine transformations to correct for geometric distortions. In our experimental setup, we found that a 0.3° skew correction provided superior alignment compared to standard rotation, accounting for non-orthogonal scanning axes.
  3. Magnetic Inversion: The model converts magnetic field data ($B_z$) into current density ($J_x, J_y$) by applying the Biot-Savart Law in the Fourier domain. A tunable "hard cut-off filter" ($k_w$) is used to suppress high-frequency noise during this conversion.

Experimental Setup and Datasets

The model was validated using a custom-fabricated 3D spiral sample designed to mimic complex internal circuitry. The sample consists of two layers with approximately nine segments of 200 µm wide wires. The scan was performed at 5000 Hz with a 1000 µA current, resulting in a dataset of 296,164 data points (254 x 1166 pixels) at a 30 µm resolution.

Key Results and Analysis

The SPIM demonstrated significant improvements in image quality and reconstruction accuracy:

  • Sharpness Improvement: Phase adjustment (at 5.8°) improved I-channel sharpness by 0.3% while reducing the blurry Q-channel sharpness by 25%, successfully isolating the signal from interference.
  • Alignment Precision: The model successfully identified and corrected a 0.3° misalignment in real-world scanning data.
  • Current Reconstruction: By setting the cut-off frequency $k_w = 25 \text{ mm}^{-1}$, the model accurately mapped the 3D path of the current through the spiral structure.
3D reconstruction of the current path through the spiral sample, demonstrating the model's ability to resolve complex vertical and lateral segments.

Conclusion

SPIM demonstrates that combining spatial analysis with physics-driven models can significantly enhance the capabilities of SQUID microscopy for semiconductor failure analysis. While the current model assumes a known depth ($z$) for the current-carrying wires, future work will focus on extending the model to resolve both lateral and vertical resolutions simultaneously and testing it on samples with known physical defects like shorts or leaky paths.

Summary updated

Abstract

The development of advanced packaging is essential in the semiconductor manufacturing industry. However, non-destructive testing (NDT) of advanced packaging becomes increasingly challenging due to the depth and complexity of the layers involved. In such a scenario, Magnetic field imaging (MFI) enables the imaging of magnetic fields generated by currents. For MFI to be effective in NDT, the magnetic fields must be converted into current density. This conversion has typically relied solely on a Fast Fourier Transform (FFT) for magnetic field inversion; however, the existing approach does not consider eddy current effects or image misalignment in the test setup. In this paper, we present a spatial-physics informed model (SPIM) designed for a 3D spiral sample scanned using Superconducting QUantum Interference Device (SQUID) microscopy. The SPIM encompasses three key components: i) magnetic image enhancement by aligning all the "sharp" wire field signals to mitigate the eddy current effect using both in-phase (I-channel) and quadrature-phase (Q-channel) images; (ii) magnetic image alignment that addresses skew effects caused by any misalignment of the scanning SQUID microscope relative to the wire segments; and (iii) an inversion method for converting magnetic fields to magnetic currents by integrating the Biot-Savart Law with FFT. The results show that the SPIM improves I-channel sharpness by 0.3% and reduces Q-channel sharpness by 25%. Also, we were able to remove rotational and skew misalignments of 0.30 in a real image. Overall, SPIM highlights the potential of combining spatial analysis with physics-driven models in practical applications.
BibTeX
@misc{senthilnath2025spatial,
  author = {J. Senthilnath and Jayasanker Jayabalan and Zhuoyi Lin and Aye Phyu Phyu Aung and Chen Hao and Kaixin Xu and Yeow Kheng Lim and F. C. Wellstood},
  title = {{A Spatial-Physics Informed Model for 3D Spiral Sample Scanned by SQUID Microscopy}},
  year = {2025},
  eprint = {2507.11853},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2507.11853},
}
Figure