A Simple and Inexpensive Electrochemical Assay for the Identification of Nitrogen Containing Explosives in the Field

Jeffrey S. Erickson, Lisa C. Shriver‐Lake, Daniel Zabetakis, David A. Stenger, Scott A. Trammell2017

TL;DR

Researchers have developed a low-cost, handheld electrochemical device for identifying explosives in the field. This system utilizes a simple wipe test and a custom-built potentiostat to generate unique electrochemical "fingerprints" of explosives, enabling rapid identification through a library-based algorithm.

What Problem Does This Paper Address?

Current methods for detecting explosives in the field often suffer from significant drawbacks. Spectroscopic techniques like IR and Raman struggle with trace detection, while colorimetric devices can produce false positives and require expensive consumables. Ion mobility spectrometers, though handheld, rely on radioactive sources. Other advanced techniques like mass spectrometry and gas chromatography are too bulky and time-consuming for immediate field use. There's a clear need for a portable, inexpensive, and reliable system that can quickly identify explosives at trace levels, especially for security and defense applications.

Methods

The core of this work is a custom-built, handheld potentiostat, heavily modified from an open-source design (CheapStat). This device is designed for field use, featuring a small footprint, low power consumption, and the ability to perform time-resolved electrochemical measurements. The key technique employed is cyclic square wave voltammetry (CSW).

The assay involves a simple wipe test: a surface is wiped with filter paper, which is then placed on a screen-printed electrode (SPE) with a potassium phosphate buffer. The potentiostat then applies a voltage sweep, and the resulting current is measured. CSW is used because the reduction of nitrogen-containing explosives at the electrode surface generates unique electrochemical signatures (peak positions and ratios) that are characteristic of their chemical structure.

To identify explosives, the researchers created a library of CSW voltammograms for 12 different compounds, including nitroaromatics, a nitramine (RDX), and a nitrate ester. A simple discrimination algorithm was developed in Excel. This algorithm has two main steps:

  1. Least Squares Fitting: The measured voltammogram is compared to each reference voltammogram in the library using a least squares fitting routine to find the best match coefficients.
  2. Correlation Calculation: A correlation function, adapted from spectral library searching, is used to further refine the match, correcting for baseline variations.

Finally, an "overall" score is calculated by combining the normalized coefficients from the fitting and the correlation, providing a quantitative measure of how well the sample matches a known explosive in the library.

Datasets

The paper describes the creation of a new dataset: a library of cyclic square wave voltammograms (CSWs) for 12 different explosive compounds. These compounds include:

  • 10 nitroaromatics: 2,4,6-trinitrotoluene (TNT), 1,3,5-trinitrobenzene (TNB), 2,4,6-Trinitrophenylmethylnitramine (Tetryl), 2,4-Dinitrotoluene (2,4-DNT), 2,6-Dinitrotoluene (2,6-DNT), 1,3-Dinitrobenzene (1,3-DNB), 4-amino-2,6-dinitrotoluene (4-am-2,6-DNT), 2-amino-4,6-dinitrotoluene (2-am-4,6-DNT), 2-nitrotoluene (2-NT), and 3-nitrotoluene (3-NT).
  • 1 nitramine: 1,3,5-Trinitroperhydro-1,3,5-triazine (RDX).
  • 1 nitrate ester: Propane-1,2,3-triyl trinitrate (NG).

These voltammograms were generated using the prototype instrument and screen-printed electrodes. The paper also presents evaluation data using these compounds in both direct sample preparation (evaporating standards onto filter paper) and dry surface sampling (wiping a benchtop).

Key Insights and Ideas

  • Electrochemical Fingerprinting: The core idea is that the complex reduction and oxidation processes of nitrogen-containing explosives at an electrode surface produce unique, measurable electrochemical signatures that can be used for identification.
  • Low-Cost Field Deployability: The development of a functional, handheld potentiostat for under $250 USD demonstrates the feasibility of creating inexpensive, yet capable, field-deployable analytical tools.
  • Wipe Test Efficacy: The study shows that a simple wipe test, combined with electrochemical analysis, can be effective for detecting explosives, even from dry surfaces.
  • Algorithm Robustness (and limitations): The developed discrimination algorithm, while simple, shows promise in identifying explosives. However, it also highlights the challenge of distinguishing between explosives with similar electrochemical behavior and the impact of noise in real-world samples.
  • Modular Design: The instrument's design allows for future expansion, such as integrating motor drivers for autonomous sampling, making it suitable for integration into robotic systems.

Key Results

  • A prototype handheld potentiostat was successfully built for approximately $250 USD.
  • The instrument is capable of performing time-resolved electrochemical measurements, including cyclic square wave voltammetry.
  • An example library of CSW voltammograms for 12 explosives was generated.
  • A simple discrimination algorithm was developed and tested, demonstrating the ability to identify explosives from both prepared samples and dry surface wipes.
  • The study showed that explosives with more distinct electrochemical features (more peaks, stronger signals) generally received higher identification scores.
  • The dry surface sampling tests revealed some false positives, particularly from fitting the noise in the sample voltammograms, but the combined scoring method (Equation 3) was able to refine the results and correctly identify the explosive in most cases.

Limitations and Future Work

  • Algorithm Refinement: The authors acknowledge that the current discrimination algorithm is simple and that further development is needed for more robust identification, especially for complex mixtures and under varying field conditions.
  • Limit of Detection/Quantification: The paper states that the assay has a limit of detection and quantification, and that below this limit, identification becomes impossible. These specific limits will be addressed in a subsequent paper.
  • Field Conditions: The current study was performed under controlled laboratory conditions. Future work will involve analyzing the instrument and algorithm under actual field conditions, characterizing explosive mixtures, and determining the dynamic range and limits of identification.
  • False Positives: The dry surface sampling tests highlighted the potential for false positives, particularly when fitting noise. Improving the algorithm to better distinguish between true signals and background noise is crucial.

Summary updated

Abstract

We report a simple and inexpensive electrochemical assay using a custom built hand-held potentiostat for the identification of explosives. The assay is based on a wipe test and is specifically designed for use in the field. The prototype instrument designed to run the assay is capable of performing time-resolved electrochemical measurements including cyclic square wave voltammetry using an embedded microcontroller with parts costing roughly $250 USD. We generated an example library of cyclic square wave voltammograms of 12 compounds including 10 nitroaromatics, a nitramine (RDX), and a nitrate ester (nitroglycine), and designed a simple discrimination algorithm based on this library data for identification.
BibTeX
@misc{erickson2017simple,
  author = {Jeffrey S. Erickson and Lisa C. Shriver‐Lake and Daniel Zabetakis and David A. Stenger and Scott A. Trammell},
  title = {{A Simple and Inexpensive Electrochemical Assay for the Identification of Nitrogen Containing Explosives in the Field}},
  year = {2017},
  doi = {10.3390/s17081769},
}

Loading related content...

Figure