A Precise Measurement of D-T Neutrons With a Single-Crystal Diamond Detector

Guangwei Huang, Chunzhi Zhou, Yiyun Zhang, Ye Chen, Kun Wu, Linxiang Li, Hongying Zhu, Zhiyuan Li, Zungang Wang, Zhiqiang Liu, Xiaoyan Yi, Jinmin LiIEEE Transactions on Nuclear Science 2021 · DOI

Abstract

Single-crystal diamond (SCD) detectors show promise as neutron spectrometers. They have been increasingly used for neutron monitoring of high-flux deuterium plasmas. In this article, a high-performance SCD detector is exposed to D-T neutrons at different angles to measure the energy spectra. The results show that the diamond detector is stable under neutron irradiation fluence of <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$1.63\times10$ </tex-math></inline-formula> <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">10</sup> n/cm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> during the 2 h testing. Its detection efficiency for <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">12</sup> C (n, <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\alpha$ </tex-math></inline-formula> ) <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">9</sup> Be is (3.31 ± 0.11) <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\times \,\, 10$ </tex-math></inline-formula> <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">−4</sup> counts/n, which is in good agreement with a Monte Carlo simulation predicted by a Geant4 simulation. The deviation in the detection efficiency between the simulation and experimental results is as low as 0.61%. In addition, a response matrix is created and Gaussian broadening has been applied to obtain a good alignment between the measured and simulated results. Finally, a variety of neutron spectrum unfolding methods, namely, the non-negative least-squares algorithm, the Gravel algorithm, the Gold algorithm, and the Lucy–Richardson algorithm, are applied and compared in detail, demonstrating that using a SCD detector, the precise energy distribution of the D-T neutrons from different angles can be obtained by exploiting the spectrum unfolding methods.
BibTeX
@article{huang2021precise,
  author = {Guangwei Huang and Chunzhi Zhou and Yiyun Zhang and Ye Chen and Kun Wu and Linxiang Li and Hongying Zhu and Zhiyuan Li and Zungang Wang and Zhiqiang Liu and Xiaoyan Yi and Jinmin Li},
  title = {{A Precise Measurement of D-T Neutrons With a Single-Crystal Diamond Detector}},
  journal = {IEEE Transactions on Nuclear Science},
  year = {2021},
  doi = {10.1109/tns.2021.3136388},
}

Loading related content...

Figure