Abstract
Graphene-based stretchable and flexible strain sensors are one of the promising “bridges” to the biomedical realm. However, enhancing graphene-based wearable strain sensors to meet the demand of high sensitivity, broad sensing range, and recoverable structure deformation simultaneously is still a great challenge. In this work, through structural design, we fabricated a simple Ecoflex/Overlapping Graphene/Ecoflex (EOGE) strain sensor by encapsulating a graphene sensing element on polymer Ecoflex substrates using a drop-casting method. The EOGE strain sensor can detect stretching with high sensitivity, a maximum gauge factor of 715 with a wide strain range up to 57%, and adequate reliability and stability over 1,000 cycles for stretching. Moreover, the EOGE strain sensor shows recoverable structure deformation, and the sensor has a steady response in the frequency disturbance test. The good property of the strain sensor is attributed to the resistance variation induced by the overlap and crack structure of graphene by structural design. The vibrations caused by sound and various body movements have been thoroughly detected, which exhibited that the EOGE strain sensor is a promising candidate for wearable biomedical electronic applications.
Introduction
The development of wearable "electronic skin" requires sensors that can mimic human skin's flexibility while maintaining high sensitivity. However, there is a persistent trade-off in materials science: sensors that are highly sensitive to tiny movements (like a pulse) often have a very limited stretching range, while those that can stretch significantly (like over a knee joint) usually lack the precision to detect subtle vibrations. Traditional metal or semiconductor-based sensors are too rigid, typically failing at less than 5% strain.
Researchers have developed a high-performance, "sandwich-structured" strain sensor by encapsulating overlapping graphene flakes between layers of Ecoflex elastomer. This sensor achieves an exceptional balance of high sensitivity (Gauge Factor up to 715) and a broad sensing range (up to 57% strain), making it capable of tracking both subtle physiological signals like vocal cord vibrations and large-scale body movements.
Methods
The authors fabricated the Ecoflex/Overlapping Graphene/Ecoflex (EOGE) sensor using a straightforward, low-cost "sandwich" approach. The process involves substrate preparation using Ecoflex, followed by drop-casting graphene ink through a polyimide (PI) tape shadow mask to create a film of overlapping flakes. Copper wires are then attached with silver paste, and the entire assembly is encapsulated with a second layer of Ecoflex.
Mechanical performance was tested using a universal testing machine integrated with a digital multimeter to record resistance changes in real-time. The team also characterized the material using Scanning Electron Microscopy (SEM) and Raman spectroscopy to verify the graphene's quality.
Characterization and Mechanism
The sensor’s high sensitivity is a result of its unique geometry. When stretched, the overlapping graphene flakes slide against each other, reducing the contact area and increasing resistance. At higher strains, micro-cracks form in the graphene layer. This combination of sliding and cracking allows for a massive change in resistance (high sensitivity) across a wide range of motion.
The "sandwich" design is crucial; by encapsulating the graphene, the Ecoflex layers force the graphene flakes back into their original overlapping positions once tension is released, allowing for a steady response over 1,000 cycles. The sensor also demonstrated frequency independence, maintaining a steady response across different frequencies (0.1 to 0.3 Hz).
Key Results
The EOGE sensor demonstrated several key performance metrics:
- Sensitivity: A maximum Gauge Factor (GF) of 715, significantly higher than many existing flexible sensors.
- Stretchability: Reliable performance up to 57% strain.
- Durability: Excellent stability over 1,000 stretching/releasing cycles at both 15% and 40% strain.
Practical applications were validated through speech recognition (distinguishing words like "one," "two," and "three" based on throat vibrations), health monitoring (capturing resting pulse and breathing rate changes), and joint tracking (monitoring neck, elbow, wrist, and knee bending).
Conclusion
While the 57% strain range is sufficient for many applications, it may still be a limiting factor for specific high-intensity athletic movements. Future work will focus on automating the fabrication process (e.g., via screen printing) to ensure scalability and exploring performance under environmental stressors like sweat or varying temperatures.