TL;DR
This paper introduces a neuromusculoskeletal (NMS) model that predicts individual muscle forces during elbow movements by fusing motion sensor data and surface electromyography (sEMG). This approach offers a more objective and detailed assessment of upper limb function, crucial for personalized rehabilitation strategies in neurorehabilitation.
What Problem Does This Paper Address?
Hemiplegia, often resulting from stroke or brain injury, significantly impairs upper limb function, hindering daily activities. While rehabilitation aims to restore function, objective evaluation of upper limb impairment and personalized treatment remain challenging. Existing methods like assessment scales are subjective, and motion capture, while objective, doesn't capture underlying neuromuscular characteristics. sEMG offers insights into muscle activation but is prone to noise and lacks deep muscle activation information. This paper addresses the need for a more comprehensive and objective method to assess upper limb function by predicting individual muscle forces, which are fundamental to movement and can reveal subtle neuromuscular deficits.
Methods
The core of the proposed method is a neuromusculoskeletal (NMS) model that integrates data from inertial sensors (for joint angle estimation) and sEMG sensors (for muscle activation).
- Joint Angle Estimation: An Extended Kalman Filter (EKF) is employed to fuse angular rate and acceleration data from an inertial sensor attached to the forearm. This approach overcomes the drift issues associated with simple gyroscope integration and provides accurate elbow joint angle estimation.
- Muscle Activation Dynamics: Raw sEMG signals are preprocessed (filtered, rectified, and normalized) to obtain muscle excitations. These excitations are then fed into a second-order discrete linear model to estimate neural activation, followed by an adjustment to account for the EMG-force relationship, resulting in muscle activations. A novel aspect here is the use of a neural mapping method to estimate activations for muscles whose sEMG was not directly measured, assuming similar activation patterns for muscles with shared innervation.
- NMS Model: This model combines muscle kinematics (derived from an OpenSim upper limb model), muscle contraction dynamics (using a Hill-type musculotendon model), joint moment estimation (summing individual muscle forces multiplied by their moment arms), and static optimization.
- Calibration and Adjustment: A key innovation is the calibration process using static optimization to tune model parameters by minimizing the error between estimated and experimental joint moments. Furthermore, a "muscle excitation adjustment" mechanism is introduced. This mechanism uses static optimization to adjust muscle excitations within a defined tolerance (Th) to better match experimental joint moments, acknowledging the inherent uncertainties and noise in sEMG signals. This trade-off aims to improve joint dynamics estimation accuracy at the cost of precise muscle excitation tracking.
Datasets
The study used data collected from four healthy male subjects performing voluntary elbow flexion and extension.
- Motion Data: Collected at 50 Hz using an MPU-9150 inertial sensor.
- sEMG Data: Recorded at 1000 Hz from specific elbow muscles (long head of biceps brachii, brachioradialis, and lateral head of triceps brachii) using the ME6000 system.
- Experimental Joint Moment: Obtained using the OpenSim Inverse Dynamics Tool.
- Experimental Muscle Synergies: Extracted using Non-negative Matrix Factorization (NMF).
No new benchmark datasets were introduced; rather, existing methods and tools (OpenSim, NMF) were integrated.
Key Insights and Ideas
- Fusion for Deeper Understanding: Combining motion and sEMG data provides a more holistic view of movement, bridging the gap between kinematic and neuromuscular assessments.
- Addressing sEMG Uncertainty: The proposed "muscle excitation adjustment" mechanism is a pragmatic approach to mitigate the impact of sEMG noise and signal limitations, allowing for more robust joint dynamics prediction.
- Subject-Specific Modeling: The calibration process allows the NMS model to adapt to individual subject characteristics, leading to more personalized and accurate predictions.
- Neural Control Insights: The muscle synergy analysis demonstrates that even with adjusted muscle excitations, the model can still reflect realistic neural control strategies, suggesting its utility in understanding how the brain controls movement.
Key Results
- Accurate Joint Angle Estimation: The EKF method achieved high accuracy in estimating elbow joint angles, with NRMSD = 0.0434 ± 0.0056 and R² = 0.9951 ± 0.0035.
- Improved Joint Moment Prediction: The proposed NMS model with the muscle excitation adjustment mechanism significantly improved joint moment estimation compared to a standard EMG-driven model. With an optimal Th value (Th=0.8), the NRMSD for joint moment was reduced to 0.0317 ± 0.0111 and R² increased to 0.9758 ± 0.0215.
- Realistic Muscle Force Prediction: The model successfully predicted individual muscle forces for elbow flexion and extension, showing distinct patterns for flexor and extensor muscles.
- Muscle Synergy Agreement: The adjusted muscle synergies showed high agreement (scalar products > 95%) with experimental synergies across subjects, indicating that the model captures underlying neural control strategies.
Limitations and Future Work
- Single DOF Joint Angle Estimation: The current joint angle estimation method is limited to one degree of freedom (DOF). Future work will involve developing a more elaborate model, potentially using a network of multiple inertial sensors, to estimate multi-DOF joint angles (e.g., shoulder and elbow).
- Neural Mapping Simplification: The neural mapping method used to estimate deep muscle activations is a simplification. Further research is needed to improve the simulation of deep muscle excitations.
- Pilot Study Scope: The study was a pilot with a limited number of subjects and movements. A more generalizable evaluation criterion requires further experiments across more individuals and tasks.
- Generalizability: While the calibration process allows for individual application, extending the model to other joints (e.g., knee, ankle) will require careful consideration of muscle selection and potential differences in measurement techniques.
Summary updated