NeurIPS 2026Coming to NeurIPS?Explore papers, orals & directions

A novel structure of silicon-on-insulator microring biosensor based on Young's two-slit interference and its simulation

Baoqing Su, Chunxia Wang, Qiang Kan, Junhua Li, Yiyang Xie, Zhenzhen Wang, Hongda ChenJournal of Semiconductors 2011

Abstract

A novel silicon-on-insulator microring biosensor based on Young's twos lit interference has been demonstrated. The transducer signal from electric field intensity distribution on the interference screen is given by using the transfer matrix method (TMM) and two-slit interference principle. The result shows that the structure we propose is advantageous for sensing as the interference pattern is very sensitive to the ambient refractive index around the microring. A small perturbation in refractive index around the microring Δnc will result in a notable shift of destructive interference points (DIPs) on the interference screen. By detecting the shift of the DIPs, the ambient refractive index change can be obtained.
BibTeX
@article{su2011novel,
  author = {Baoqing Su and Chunxia Wang and Qiang Kan and Junhua Li and Yiyang Xie and Zhenzhen Wang and Hongda Chen},
  title = {{A novel structure of silicon-on-insulator microring biosensor based on Young's two-slit interference and its simulation}},
  journal = {Journal of Semiconductors},
  year = {2011},
  doi = {10.1088/1674-4926/32/7/074010},
}

Loading related content...