A novel anthropometric method to accurately evaluate tissue deformation

Chongyang Ye, Xiaolu Li, Haiyan Song, Yu Shi, Ruixin Liang, Jun Zhang, Ka Po Lee, Zhaolong Chen, Beibei Zhou, Raymond Kai‐Yu Tong, Kit‐Lun Yick, Sun‐pui Ng, Joanne YipFrontiers in Bioengineering and Biotechnology 2025 · DOI

Abstract

This anthropometric approach is an invaluable tool for evaluating tissue deformation patterns, thus providing key insights for sportswear designers to optimize garment performance and design.

Introduction

The design of high-performance compression sportswear, such as leggings intended to enhance circulation and muscle stability, hinges on a precise understanding of how these garments interact with human soft tissue. While the mechanical benefits of compression are well-documented, quantifying the resulting "tissue deformation"—the physical displacement and reshaping of the body's soft tissues—remains a significant challenge.

Traditional measurement techniques, such as interface pressure sensors, only capture the interaction at the skin-fabric boundary and fail to account for the internal displacement of tissue. Furthermore, while 3D body scanning provides a visual representation, it often struggles with motion artifacts, making it difficult to distinguish between garment-induced deformation and natural body movement. This research introduces a novel method to bridge the gap between static theoretical models and the dynamic reality of a body in motion.

Methodology: A Dual-Track Approach

To address these limitations, researchers developed a high-precision anthropometric method that integrates analytical modeling with experimental 4D body scanning.

Analytical Modeling

The team utilized the Boussinesq solution, a cornerstone of classical elastic theory, alongside the stress function method to predict tissue deformation. By simplifying the leg's cross-section to a circular geometry, they were able to apply continuum mechanics to estimate how much tissue would displace based on the mechanical properties of the fabric.

4D Scanning and Image Recognition

Experimental validation was conducted using a 3dMD scanning system. A female subject with a BMI > 24 was scanned in both static "A-poses" and during 60 Hz vertical vibrations to simulate high-impact movement. The choice of an overweight classification ensured more pronounced soft tissue deformation for clearer model validation.

Experimental setup for 4D scanning of tissue deformation under compression.

To overcome the "noise" of body motion, the researchers developed a novel image recognition algorithm in MATLAB. This algorithm identifies landmarks on the leg's cross-section and calculates the "centroid" of the limb. By measuring radial distances from this centroid to the skin surface in both "baseline" (thong-only) and "compressed" (leggings-on) states, the team could isolate the net deformation caused by the garment, effectively filtering out motion artifacts.

Material Characterization

The study evaluated five different legging samples with varying compositions of Nylon, Elastane, Polyester, and Spandex. The mechanical properties of these fabrics, including Young’s modulus and Poisson’s ratio, were determined using Instron 4411 tension testing and KES-FB1 shear testing systems to provide accurate inputs for the analytical model.

Key Insights and Results

The study revealed several critical factors influencing tissue deformation:

  • Material Stiffness: The Young’s modulus of the fabric was identified as the primary driver of deformation. Stiffer leggings (Type 4) produced significantly greater tissue displacement than more flexible samples (Type 5).
  • Anatomical Variation: Deformation is not uniform across the lower body. The highest displacement occurred at the hip—where tissue is softest and garment tension is often highest—and decreased progressively toward the ankle (e.g., ~6.4 mm at the hip vs. 0.95 mm at the ankle for Type 1 leggings).
  • Dynamic vs. Static Conditions: Dynamic deformation values were consistently higher than static ones due to inertial forces acting on the soft tissue during vibration. This suggests that static measurements alone are insufficient for optimizing sportswear for active use.

The analytical model demonstrated exceptional accuracy, with mean deviations from experimental data of only 1.15 mm in static conditions and 2.36 mm in dynamic conditions.

Conclusion and Future Work

This novel method provides a robust framework for quantifying tissue deformation with high precision. While the current model uses simplified circular geometry and assumes purely elastic material behavior, it offers a significant leap forward in sportswear engineering. Future research will focus on incorporating viscoelastic properties and testing a broader range of body morphologies to enhance the model's generalizability and real-world applicability.

Summary updated

Abstract

This anthropometric approach is an invaluable tool for evaluating tissue deformation patterns, thus providing key insights for sportswear designers to optimize garment performance and design.
BibTeX
@inproceedings{ye2025novel,
  author = {Chongyang Ye and Xiaolu Li and Haiyan Song and Yu Shi and Ruixin Liang and Jun Zhang and Ka Po Lee and Zhaolong Chen and Beibei Zhou and Raymond Kai‐Yu Tong and Kit‐Lun Yick and Sun‐pui Ng and Joanne Yip},
  title = {{A novel anthropometric method to accurately evaluate tissue deformation}},
  booktitle = {Frontiers in Bioengineering and Biotechnology},
  year = {2025},
  doi = {10.3389/fbioe.2025.1632806},
}
Figure