A Motion-Robust Slice-to-Volume Reconstruction Framework for Fetal Brain MRI
Abstract
Volumetric reconstruction of fetal brains from multiple stacks of MR slices is challenging due to severe subject motion and image artifacts. We propose a deep learning method to solve the slice-to-volume reconstruction problem in two stages. First, a Transformer network is used to correct motion between slices by registering the input slices to a 3D canonical space. Second, an implicit neural network reconstructs the 3D volume by learning a continuous 3D representation of the fetal brain from the 2D observations. Results show that our method achieves high reconstruction quality and outperforms existing state-of-the-art methods in presence of severe fetal motion.
BibTeX
@inproceedings{xu2024motion,
author = {Junshen Xu and Daniel Moyer and Borjan Gagoski and P. Ellen Grant and Polina Golland and Juan Eugenio Iglesias and Elfar Adalsteinsson},
title = {{A Motion-Robust Slice-to-Volume Reconstruction Framework for Fetal Brain MRI}},
booktitle = {Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition},
year = {2024},
doi = {10.58530/2023/0082},
}Ask Althea to put this paper to the test.