A micro-CT-based method for quantitative brain lesion characterization and electrode localization

Javier Masís, David Mankus, Steffen B. E. Wolff, Grigori Guitchounts, Maximilian Joesch, David CoxScientific 2018 · DOI

Abstract

Lesion verification and quantification is traditionally done via histological examination of sectioned brains, a time-consuming process that relies heavily on manual estimation. Such methods are particularly problematic in posterior cortical regions (e.g. visual cortex), where sectioning leads to significant damage and distortion of tissue. Even more challenging is the post hoc localization of micro-electrodes, which relies on the same techniques, suffers from similar drawbacks and requires even higher precision. Here, we propose a new, simple method for quantitative lesion characterization and electrode localization that is less labor-intensive and yields more detailed results than conventional methods. We leverage staining techniques standard in electron microscopy with the use of commodity micro-CT imaging. We stain whole rat and zebra finch brains in osmium tetroxide, embed these in resin and scan entire brains in a micro-CT machine. The scans result in 3D reconstructions of the brains with section thickness dependent on sample size (12-15 and 5-6 microns for rat and zebra finch respectively) that can be segmented manually or automatically. Because the method captures the entire intact brain volume, comparisons within and across studies are more tractable, and the extent of lesions and electrodes may be studied with higher accuracy than with current methods.

Introduction

In neuroscience, verifying the exact location of a lesion or a recording electrode is a fundamental but often frustrating task. The traditional "gold standard" involves physical histology: freezing or paraffin-embedding a brain, slicing it into thin sections, staining them, and manually estimating volumes. This process is plagued by tissue distortion (warping, tearing, or shrinkage), loss of 3D context between sections, and significant labor requirements. Furthermore, sampling bias often limits researchers to a single slicing orientation, potentially obscuring critical features.

This paper introduces a non-destructive, 3D imaging workflow for small animal brains that addresses these limitations. By combining standard electron microscopy staining with commodity micro-CT, researchers can perform "virtual histology," allowing for precise, labor-efficient quantification of lesions and electrode localization without the tissue distortion inherent in physical sectioning.

Methods

The proposed workflow bridges the gap between high-resolution electron microscopy (EM) and macro-scale CT scanning. The process involves several key steps:

  1. Staining: Whole brains are stained with osmium tetroxide ($OsO_4$), a heavy metal stain typically used in EM to provide contrast for lipids. The innovation lies in using an aqueous solution of osmium for two weeks, which ensures the stain penetrates the entire depth of the tissue.
  2. Embedding: The stained brain is embedded in a hard resin, creating a stable, permanent sample.
  3. Micro-CT Scanning: Using a standard micro-CT machine, a 3D digital volume is generated. This allows for "virtual slicing" in any orientation (coronal, sagittal, horizontal, or arbitrary angles) post-collection.
  4. Artifact Mitigation: To handle "ringing" artifacts from metal electrodes, a metal filter is used to harden the X-ray beam.
Workflow for micro-CT-based brain imaging and analysis.

Results and Discussion

The method was validated using rat and zebra finch brains. A critical technical insight was that aqueous osmium penetrates deep tissue much better than buffered osmium, likely because water helps permeabilize cell membranes.

Accuracy and Efficiency

Volume estimates for deep brain lesions were highly concordant between micro-CT and traditional histology (e.g., 34 $mm^3$ via CT vs. 32 $mm^3$ via traditional methods). Once the staining period is complete, the digital analysis is significantly less labor-intensive than manual histology.

Electrode Localization and Resolution

The method successfully localized single tetrodes, 16-tetrode arrays, and silicon probes. 3D reconstructions revealed that tetrodes often experience significant "drift" or bending during penetration—details nearly impossible to track with 2D physical slices. The method scales well; while rat brains yield 12–15 $\mu$m resolution, smaller samples like zebra finch brains can reach resolutions under 6 $\mu$m.

3D reconstruction and multi-planar virtual slices of a zebra finch brain.

Limitations

While powerful, the heavy osmium staining makes tissue incompatible with traditional secondary histology, such as immunohistochemistry (IHC). Additionally, scaling to larger brains (e.g., macaques) would require significantly longer incubation times.

Conclusion

This micro-CT-based approach provides a robust, non-destructive alternative to traditional histology. By preserving the entire intact brain volume in a digital format, it enables more accurate lesion characterization and electrode localization, facilitating better comparisons within and across neuroscience studies. Future work may involve creating standardized "average brain" atlases for automated quantification.

Summary updated

Abstract

Lesion verification and quantification is traditionally done via histological examination of sectioned brains, a time-consuming process that relies heavily on manual estimation. Such methods are particularly problematic in posterior cortical regions (e.g. visual cortex), where sectioning leads to significant damage and distortion of tissue. Even more challenging is the post hoc localization of micro-electrodes, which relies on the same techniques, suffers from similar drawbacks and requires even higher precision. Here, we propose a new, simple method for quantitative lesion characterization and electrode localization that is less labor-intensive and yields more detailed results than conventional methods. We leverage staining techniques standard in electron microscopy with the use of commodity micro-CT imaging. We stain whole rat and zebra finch brains in osmium tetroxide, embed these in resin and scan entire brains in a micro-CT machine. The scans result in 3D reconstructions of the brains with section thickness dependent on sample size (12-15 and 5-6 microns for rat and zebra finch respectively) that can be segmented manually or automatically. Because the method captures the entire intact brain volume, comparisons within and across studies are more tractable, and the extent of lesions and electrodes may be studied with higher accuracy than with current methods.
BibTeX
@inproceedings{masis2018micro,
  author = {Javier Masís and David Mankus and Steffen B. E. Wolff and Grigori Guitchounts and Maximilian Joesch and David Cox},
  title = {{A micro-CT-based method for quantitative brain lesion characterization and electrode localization}},
  booktitle = {Scientific},
  year = {2018},
  doi = {10.1038/s41598-018-23247-z},
}
Figure