NeurIPS 2026Coming to NeurIPS?Explore papers, orals & directions

A Method for Parameter Identification of Composite Beam Piezoelectric Energy Harvester

Xuhui Zhang, Chao Zhang, Lin Wang, Luyang Chen, Xiaoyu Chen, Dongmei Xu, Hongwei Fan, Fulin Zhu2021

TL;DR

This paper introduces a novel method for accurately identifying the mechanical and electrical parameters of a composite beam piezoelectric energy harvester (PEH-C). By analyzing the system's voltage response under both short-circuit and open-circuit conditions, the researchers developed a technique that significantly improves the accuracy of dynamic modeling, crucial for optimizing PEH-C design and performance.

What Problem Does This Paper Address?

Vibration energy harvesting, particularly using piezoelectric materials, holds immense promise for powering low-power wireless sensors in challenging environments like coal mines. However, accurately modeling these systems is difficult due to complex nonlinearities and the challenge of precisely determining their mechanical and electrical parameters. Traditional modeling methods often lead to errors in predicting system behavior and experimental results. This paper tackles this challenge by proposing a robust parameter identification method specifically for a linear-arch composite beam piezoelectric energy harvester, aiming to bridge the gap between theoretical models and real-world performance.

Methods

The core of this paper lies in its parameter identification methodology, which leverages the distinct voltage response characteristics of the PEH-C under different electrical conditions.

  • Short-Circuit Condition (Mechanical Parameter Identification):
    • The researchers analyze the system's transient excitation response under short-circuit conditions.
  • They employ the backbone curve theory and the logarithmic attenuation method to extract mechanical parameters.
  • Specifically, the backbone curve is fitted using a least-squares method to determine stiffness coefficients (linear and nonlinear), while the logarithmic attenuation of the envelope curve (obtained via Hilbert transform) is used to identify damping coefficients.
  • Open-Circuit Condition (Electrical Parameter Identification):
    • Under open-circuit conditions, the electrical equations are analyzed alongside the voltage response.
  • The method utilizes the system's output voltage, voltage change rate, and velocity signals.
  • By fitting these signals (often using least-squares) and substituting them into derived analytical expressions, the electromechanical coupling coefficient and equivalent capacitance coefficient are determined.

The paper also utilizes the Runge-Kutta numerical method for solving the dynamic equations and the Hilbert transform for signal processing (envelope extraction).

Datasets

The paper does not introduce new benchmark datasets. Instead, it relies on:

  • Numerical Simulation Data: The authors generate simulation data based on their theoretical model and the parameters provided in Table 1. This data is used for initial verification of the identification algorithm.
  • Experimental Data: An experimental platform was constructed to collect real-world data from the PEH-C. This experimental data is then used to validate the accuracy of the identified parameters.

Key Insights and Ideas

  • Dual-Condition Identification: The ingenious use of both short-circuit and open-circuit conditions allows for the independent and accurate identification of distinct sets of parameters (mechanical vs. electrical), which is a significant advantage over methods relying on a single condition.
  • Bridging Theory and Experiment: The paper demonstrates a strong synergy between theoretical modeling, numerical simulation, and experimental validation. The proposed identification method is shown to be effective across all these stages.
  • Importance of Nonlinearity: The method explicitly accounts for nonlinear stiffness, which is crucial for accurately modeling the behavior of composite beam structures under vibration.
  • Practical Applicability: The construction of an experimental platform and the subsequent verification highlight the practical relevance and applicability of the proposed identification technique for real-world PEH-C systems.

Key Results

The parameter identification method demonstrated high accuracy in both numerical simulations and experimental verification:

  • Mechanical Parameters:
    • Linear stiffness coefficient (α): Error < 0.5%
    • Nonlinear stiffness coefficient (β): Error < 1.5%
    • Damping coefficient (c): Error ~ 4.5%
  • Electrical Parameters:
    • Electromechanical coupling coefficient (θ): Error ~ 0.11%
    • Equivalent capacitance coefficient (Cp): Error ~ 0.13%

These errors are consistently reported as being within an acceptable range (generally less than 5%), indicating the robustness and reliability of the proposed method. The paper also shows that the theoretical analysis is consistent with experimental results.

Limitations and Future Work

  • Limitations:
    • The paper acknowledges that some asymmetry in the voltage signal might be due to manufacturing errors in the PEH-C and the arched section.
  • The fitting of the first harmonic for electrical parameter identification can introduce minor errors.
  • Future Work:
    • The authors suggest that this parameter identification method is significant for guiding theoretical modeling under complex nonlinear conditions and improving the optimization of system parameters. While not explicitly stated as future work, the successful validation implies potential for application to other PEH designs or more complex vibration scenarios.

Summary updated

BibTeX
@misc{zhang2021method,
  author = {Xuhui Zhang and Chao Zhang and Lin Wang and Luyang Chen and Xiaoyu Chen and Dongmei Xu and Hongwei Fan and Fulin Zhu},
  title = {{A Method for Parameter Identification of Composite Beam Piezoelectric Energy Harvester}},
  year = {2021},
  doi = {10.3390/s21217213},
}
Figure