Abstract
The BES Collaboration presents a high-precision measurement of the $\psi(2S)$ meson's fundamental properties using the BESII detector at the Beijing Electron Positron Collider (BEPC). By conducting a sophisticated energy scan across the resonance peak, the study determined the mass, total width, and branching fractions for major decay modes. Notably, this work provides the first direct measurement of the $\psi(2S) \to \pi^+\pi^-J/\psi$ partial width, resolving long-standing discrepancies in charmonium physics data.
Introduction
Charmonium states, consisting of a charm quark and an anti-charm quark, provide a unique environment for testing Quantum Chromodynamics (QCD). The $\psi(2S)$ meson, the first radial excitation of the $J/\psi$, is a critical "standard candle" for calibrating experimental measurements in high-energy physics. Despite its discovery in 1974, the resonance parameters of the $\psi(2S)$—including its total width ($\Gamma_t$) and specific branching fractions—remained inconsistently measured by the early 2000s. This study aims to provide a definitive, high-precision set of parameters to resolve these conflicts.
Experimental Method
The measurement was performed using the BESII detector at the Beijing Electron Positron Collider (BEPC). The core of the experiment was a "resonance scan" involving 24 distinct center-of-mass energy points ranging from 3.67 GeV to 3.71 GeV.
The analysis involved a simultaneous likelihood fit of four primary final states: hadrons, $\pi^+\pi^-J/\psi$, $\mu^+\mu^-$, and $e^+e^-$. The latter was primarily used for luminosity calibration via Bhabha scattering. To isolate these signals, rigorous event selection criteria were applied. For leptonic channels, normalized track momenta ($p/E_{beam}$) were used to distinguish signal events from background and radiative processes.
Theoretical corrections were applied to account for Initial State Radiation (ISR), which smears the collision energy. Luminosity was determined iteratively using the $e^+e^- \to e^+e^-$ process to ensure precise normalization at each energy point.
Results
The simultaneous fit yielded high-precision values for the $\psi(2S)$ resonance parameters. The total width was measured to be $264 \pm 27$ keV, significantly lower than the previous Particle Data Group (PDG) world average of 300 keV. This indicates a longer lifetime for the $\psi(2S)$ state than previously assumed.
Key branching fractions and partial widths determined in this study include:
- Hadronic Branching Fraction ($B_h$): $(97.79 \pm 0.15)\%$
- Leptonic Branching Fraction ($B_l$): $(0.93 \pm 0.08)\%$
- $\pi^+\pi^-J/\psi$ Branching Fraction: $(32.3 \pm 1.4)\%$
- $\pi^+\pi^-J/\psi$ Partial Width: $85.4 \pm 8.7$ keV
The direct measurement of the $\pi^+\pi^-J/\psi$ partial width is a significant advancement, as previous values were typically inferred from ratios rather than measured directly from the resonance curve.
Discussion and Conclusion
The results from the BESII detector provide a more consistent and precise description of the $\psi(2S)$ resonance. By assuming lepton universality—a fundamental principle of the Standard Model—the team was able to further constrain the fit and improve the reliability of the leptonic branching fractions.
While statistical errors were minimized, the measurement remains dominated by systematic uncertainties, particularly those related to detector acceptance (ranging from 2% to 10%) and the precision of the beam energy (0.10 MeV). Future experiments at upgraded facilities like BEPCII are expected to address these systematic hurdles, pushing the precision of charmonium spectroscopy into the sub-percent regime.
Summary updated