A Highly Sensitive Fiber-Optic Fabry-Perot Interferometer Based on Internal Reflection Mirrors for Refractive Index Measurement

Xuefeng Li, Yujiao Shao, Yuan Yu, Yin Zhang, Shaowen Wei2016

TL;DR

This paper introduces a novel fiber-optic Fabry-Perot interferometer (FFPI) sensor that utilizes internal reflection mirrors fabricated with gold thin films. This design achieves high sensitivity and a wide measurement range for refractive index (RI) detection, overcoming limitations of previous sensors that struggled with media RIs close to that of the optical fiber.

What Problem Does This Paper Address?

Refractive index (RI) is a crucial parameter for characterizing analytes across various fields, including clinical diagnostics, pharmaceuticals, and environmental monitoring. Fiber-optic sensors offer advantages like immunity to electromagnetic interference and compactness, making them attractive for RI measurement. However, existing FFPI sensors face challenges:

  • Limited RI Range: When the RI of the measured medium is close to that of the optical fiber, light reflection is weak, leading to poor performance and reduced accuracy.
  • Temperature Cross-Sensitivity: Many sensors are affected by temperature fluctuations, requiring complex compensation or limiting their applicability.
  • Complex Structures and Cost: Some advanced sensors, like those using surface plasmon resonance (SPR), can be expensive and have intricate fabrication processes.

This paper aims to address these limitations by proposing a highly sensitive FFPI sensor with a wider RI measurement range and improved stability.

Methods

The core innovation lies in the sensor head's design and fabrication:

  • Open Micro-Cavity: A micro-cavity is directly machined into a single-mode fiber (SMF). This open design allows for a small sample volume and free flow of the measuring medium.
  • Internal Reflection Mirrors: Instead of relying on external reflections or complex coatings on the entire cavity, gold thin films are sputtered onto the inner surfaces of the micro-cavity. These films act as a semi-transparent mirror (STM) and a total-reflection mirror (TRM).
  • Gold Thin Films: The key advantage of gold thin films is that their reflectivity is largely independent of the surrounding medium's RI. This circumvents the problem of weak reflections when the medium's RI matches the fiber's RI. Different thicknesses of gold are sputtered to achieve the desired semi-transparent and total-reflection properties.
  • Fabrication: The micro-cavity is fabricated using focused ion beam (FIB) milling. Gold thin films are then applied via vacuum sputtering.
  • RI Measurement Principle: The sensor operates based on the interference of light reflected from the two internal mirrors. Changes in the refractive index of the medium within the micro-cavity alter the optical path length, causing a shift in the interference spectrum (specifically, the position of interference minima).
  • Temperature Compensation: A formula is derived to account for the thermal expansion of the silica fiber, enabling accurate RI measurements at different temperatures.

Datasets

Not discussed in the paper. The evaluation relies on measurements of known liquids (air, pure water, methanol, acetone) and a refractive index matching material (RIMM) with a known temperature-dependent RI.

Key Insights and Ideas

  • Internal Mirrors are Key: Sputtering gold films on the inner surfaces of the micro-cavity is a clever way to create stable, RI-independent reflective surfaces, directly addressing the core limitation of previous FFPI sensors.
  • Gold's Versatility: By controlling the thickness of the gold films, the authors can create both a semi-transparent mirror (STM) and a total-reflection mirror (TRM), essential for Fabry-Perot interferometry.
  • Wide RI Range Achieved: The sensor demonstrates consistent fringe visibility and signal intensity even when the medium's RI is close to or exceeds that of the optical fiber (e.g., RI of 1.6 vs. fiber RI of ~1.46).
  • Temperature Stability is Manageable: While temperature affects the cavity length, a derived formula effectively compensates for this, allowing for accurate RI measurements across a range of temperatures.
  • Compactness and Simplicity: The open micro-cavity design allows for small sample volumes and a relatively simple setup, making it suitable for microanalysis.

Key Results

  • High Fringe Visibility: The fabricated sensor maintains fringe visibilities exceeding 15 dB over a wide RI measurement range.
  • High Sensitivity: The sensor exhibits an RI sensitivity higher than 1160 nm/RIU.
  • Excellent RI Resolution: The RI resolution is demonstrated to be better than 1.0 × 10⁻⁶ RIU for small RI changes and better than 1.0 × 10⁻⁴ RIU for absolute RI measurements.
  • Accurate RI Measurements: The sensor accurately measured the RIs of common liquids (pure water, methanol, acetone) and a temperature-dependent RIMM, with results aligning with accepted values and manufacturer data.
  • Temperature Compensation Verified: The sensor's performance was evaluated across a temperature range of -20 to 80 °C, showing good agreement with expected RIMM behavior after compensation.

Limitations and Future Work

  • Transmission Losses: The open micro-cavity, while beneficial for sample handling, leads to light beam divergence and transmission losses (around 12 dB). The authors suggest reducing micro-cavity length to mitigate this, but this would necessitate a wider wavelength range for evaluation, increasing system cost.
  • Non-Flat Baselines: Slight misalignment during FIB milling can cause non-flat interference spectra baselines, affecting output power towards longer wavelengths. Optimizing the FIB milling process is planned for future work.
  • FIB Fabrication Cost/Time: The authors acknowledge that FIB milling is time-consuming and costly. They suggest that femtosecond laser micromachining techniques, while still under investigation for reliability and mass production, could be a more practical alternative for future commercial devices.
  • Future Work: The authors plan to optimize the FIB milling process for better measurement performance and explore alternative fabrication methods like femtosecond laser micromachining for mass production and cost reduction.

Summary updated

BibTeX
@misc{li2016highly,
  author = {Xuefeng Li and Yujiao Shao and Yuan Yu and Yin Zhang and Shaowen Wei},
  title = {{A Highly Sensitive Fiber-Optic Fabry-Perot Interferometer Based on Internal Reflection Mirrors for Refractive Index Measurement}},
  year = {2016},
  doi = {10.3390/s16060794},
}

Loading related content...

Figure