Introduction
Biological thiols (biothiols), such as cysteine (Cys) and glutathione (GSH), are essential for maintaining cellular health and physiological homeostasis. Abnormal fluctuations in biothiol levels are often indicative of serious medical conditions, including cardiovascular disease, liver damage, and neurodegenerative disorders like Alzheimer’s. While traditional analytical techniques such as high-performance liquid chromatography (HPLC) and mass spectrometry provide high accuracy, they are often limited by high costs, long processing times, and the need for specialized equipment.
Fluorescence-based sensing has emerged as a powerful alternative due to its high sensitivity and rapid response. However, single-emission probes are frequently affected by environmental factors like probe concentration and light source fluctuations. To overcome these limitations, researchers are developing ratiometric sensors that utilize the ratio of two distinct emission peaks, providing a built-in self-calibration mechanism for more robust and reliable detection.
Methodology
In this study, a novel dual-emitting sensor was developed using two-dimensional (2D) nickel-based metal-organic framework (Ni-MOF) nanosheets as a stable matrix. The synthesis process involved two primary stages:
- Nanosheet Synthesis: 2D Ni-MOF nanosheets were first synthesized via a solvothermal method.
- Post-Synthesis Modification (PSM): The matrix was functionalized by incorporating Europium ($Eu^{3+}$) and Silver ($Ag^+$) ions.
- Europium ($Eu^{3+}$): Provides a sharp red emission at 615 nm through the "antenna effect," where the MOF's organic ligands absorb light and transfer energy to the metal ion.
- Silver ($Ag^+$): Doping with $Ag^+$ ions was found to modulate the fluorescence properties, specifically enhancing the green emission of the organic ligand at 524 nm.
This dual-functionalization resulted in the Ag/Eu@Ni-MOF probe, which features two distinct luminescence centers.
Results and Discussion
Sensing Mechanism
The ratiometric sensing capability of Ag/Eu@Ni-MOF is driven by the high affinity of biothiols for silver. When Cys or GSH is introduced, the thiol groups (-SH) bind strongly to the $Ag^+$ ions, disrupting the coordination between the silver and the MOF ligand. This interaction weakens the $Ag^+$ influence on the energy transfer process, significantly quenching the green ligand luminescence (524 nm) while the red $Eu^{3+}$ emission (615 nm) remains stable. This differential response allows for precise ratiometric quantification.
Analytical Performance
The sensor demonstrated exceptional performance in aqueous solutions:
- Sensitivity: The Limit of Detection (LOD) was calculated at 0.20 μM for Cysteine and 0.17 μM for Glutathione.
- Linearity: A wide linear response range was observed between 5 and 250 μM for both biothiols.
- Stability: The fluorescence of the Ag/Eu@Ni-MOF probe remains stable across a broad, physiologically relevant pH range (4.0 to 8.0).
Visual and Biological Validation
One of the most significant advantages of this probe is its potential for visual diagnostics. In the presence of biothiols, the fluorescence color shifts from a yellow-green hue to a distinct red, a change that can be observed with the naked eye under a UV lamp. Furthermore, the probe was successfully applied to determine biothiol content in human serum samples with recovery rates between 92% and 105%, proving its efficacy in complex biological environments.
Conclusion
This work validates the use of 2D Ni-MOF nanosheets as a stable and effective matrix for constructing luminescent ratiometric sensors. The Ag/Eu@Ni-MOF probe offers high sensitivity, a wide linear range, and the capability for visual detection, making it a promising candidate for point-of-care testing (POCT) in disease diagnosis. While the material is temperature-sensitive, this property follows a predictable linear relationship that could be accounted for in clinical settings or potentially utilized for dual-sensing applications.
Summary updated