A Double-Blind, Randomized, Sham-Controlled Trial of the Effect of a Radiation-Attenuating Drape on Radiation Exposure to Endoscopy Staff During ERCP
Abstract
The addition of a radiation-attenuating drape around the image intensifier during ERCP significantly decreases radiation exposure to endoscopists and staff by ∼90%.
BibTeX
@article{muniraj2015double,
author = {Thiruvengadam Muniraj and Harry R. Aslanian and Loren Laine and James J. Farrell and Maria Ciarleglio and Yanhong Deng and Henry C. Ho and Priya A. Jamidar},
title = {{A Double-Blind, Randomized, Sham-Controlled Trial of the Effect of a Radiation-Attenuating Drape on Radiation Exposure to Endoscopy Staff During ERCP}},
journal = {The American Journal of Gastroenterology},
year = {2015},
doi = {10.1038/ajg.2015.85},