A Comparison Study between Two MPPT Control Methods for a Large Variable-Speed Wind Turbine under Different Wind Speed Characteristics

Dongran Song, Jian Yang, Mei Su, Anfeng Liu, Yao Liu, Young Hoon JooEnergies 2017 · DOI

TL;DR

This paper compares two Maximum Power Point Tracking (MPPT) control methods, Optimal Torque (OT) and Tip Speed Ratio (TSR), for a large variable-speed wind turbine. The TSR method, using an estimated wind speed, shows slightly better energy capture but at the cost of increased component loads and power variations compared to the standard OT method.

What Problem Does This Paper Address?

Wind energy is a rapidly growing sector, and maximizing energy capture from wind turbines (WTs) is crucial for cost-effectiveness. Variable-speed wind turbines (VSWTs) employ Maximum Power Point Tracking (MPPT) algorithms to achieve this. However, the performance of these MPPT methods can be significantly influenced by the WT's inherent inertia and the complex characteristics of wind speed (like turbulence). Existing studies often overlook these factors, leading to a need to understand how different MPPT strategies perform under realistic, varying wind conditions, especially for large-scale WTs. This paper aims to clarify these performance differences between two common MPPT approaches.

Methods

The study compares two MPPT control methods:

  • Optimal Torque (OT) Control: This is a standard method used in commercial WTs. It's an indirect power controller that aims to maximize mechanical power by controlling the generator torque. The paper describes a PI-based implementation with a gain scheduling unit and a mode selection unit.
  • Tip Speed Ratio (TSR) Control: This method aims to maintain the optimal tip-speed ratio (TSR) for maximum power extraction. A key aspect here is the use of an estimated wind speed, rather than direct measurement, making it cost-effective. The paper details a TSR controller that utilizes a non-standard Extended Kalman Filter (EKF)-based wind speed estimator and a speed tracking controller.

The WT model used for simulations is a 1.5 MW doubly-fed induction generator (DFIG) with a 82m rotor diameter. Simulations were performed using the industry-standard software "Bladed."

Datasets

Not discussed in the paper. The study uses simulated wind conditions based on the IEC-standard for design load case 1.1, defining five different simulation cases with varying mean wind speeds and turbulence intensities.

Key Insights and Ideas

  • TSR's Energy Edge, OT's Load Advantage: The TSR controller, using estimated wind speed, generally captures slightly more wind energy than the OT controller. However, this comes with the trade-off of increased power variations and higher loads on WT components.
  • Inertia Matters: The inertia of large WTs plays a significant role, causing a delayed response in both controllers. This delay limits the ability to further optimize wind energy capture and contributes to power reduction.
  • Turbulence's Dual Impact: Increased turbulence intensity (TI) leads to reduced power reduction (meaning more power is captured relative to the theoretical maximum) but also increases power variation.
  • Mean Wind Speed's Influence: Higher mean wind speeds, especially when approaching the rated speed, cause both controllers to operate closer to their rated capacity, leading to similar performance trends.
  • Wind Speed Estimation is Key: The effectiveness of the TSR controller hinges on the accuracy of its wind speed estimator, which the paper demonstrates to be reliable.

Key Results

  • Power Production: The TSR controller consistently produced slightly more output power than the OT controller across the tested cases (ranging from 0.1% to 1.4% increase).
  • Power Variation: The TSR controller exhibited significantly higher power variation (42.7% increase in Case 1, down to -1.9% in Case 5) compared to the OT controller.
  • Component Loads: Damage Equivalent Loads (DELs) for key components (tower bottom, yaw bearing, blade root, fixed hub) were generally higher for the TSR controller, especially at higher turbulence intensities. For example, at TI = 0.14, DELs for the TSR controller were 9.9% to 14.4% higher than the OT controller.
  • Power Reduction: Both controllers experienced power reduction, which was more pronounced at higher turbulence intensities.
  • TSR Tracking: The TSR controller maintained the estimated TSR closer to the optimal value (9.5) compared to the OT controller, which showed more fluctuations.

Limitations and Future Work

  • Component Loads vs. Energy Capture: The study highlights a trade-off: maximizing energy capture (TSR) comes at the expense of increased component loads, which can impact WT lifespan. Designers must choose based on their priorities.
  • Inertia-Induced Delays: The inherent inertia of large WTs limits the responsiveness of both controllers, leading to power reduction and delayed responses.
  • Need for Advanced Control: The paper concludes that to further improve MPPT capability for large VSWTs, advanced control methods that incorporate wind speed prediction are necessary.
  • Unknown/Uncertain Cp: If the WT's aerodynamic power coefficient (Cp) is unknown or uncertain, an adaptive method would be required to track the real MPP.

Summary updated

Abstract

Variable speed wind turbines (VSWTs) usually adopt a maximum power point tracking (MPPT) method to optimize energy capture performance. Nevertheless, obtained performance offered by different MPPT methods may be affected by the impact of wind turbine (WT)’s inertia and wind speed characteristics and it needs to be clarified. In this paper, the tip speed ratio (TSR) and optimal torque (OT) methods are investigated in terms of their performance under different wind speed characteristics on a 1.5 MW wind turbine model. To this end, the TSR control method based on an effective wind speed estimator and the OT control method are firstly presented. Then, their performance is investigated and compared through simulation test results under different wind speeds using Bladed software. Comparison results show that the TSR control method can capture slightly more wind energy at the cost of high component loads than the other one under all wind conditions. Furthermore, it is found that both control methods present similar trends of power reduction that is relevant to mean wind speed and turbulence intensity. From the obtained results, we demonstrate that, to further improve MPPT capability of large VSWTs, other advanced control methods using wind speed prediction information need to be addressed.