A Clinical Guideline Driven Automated Linear Feature Extraction for Vestibular Schwannoma

Navodini Wijethilake, Steve Connor, Anna Oviedova, Rebecca Burger, Tom Vercauteren, Jonathan ShapeyarXiv 2023 · DOI · OpenReview

TL;DR

This paper presents an automated system for extracting key linear measurements of Vestibular Schwannoma (VS) from MRI scans, mimicking clinical guidelines. By combining deep learning-based segmentation with a novel decision algorithm, the system aims to provide clinicians with accurate, standardized tumor measurements, reducing manual effort and potential subjectivity.

What Problem Does This Paper Address?

Vestibular Schwannoma (VS), a common benign brain tumor, requires careful monitoring and treatment decisions. Clinicians currently rely on manual measurements of tumor size, particularly distinguishing between intra- and extra-meatal portions, to track progression and guide interventions like surgery or radiosurgery. This manual process is time-consuming, labor-intensive, and prone to variability and subjectivity, potentially impacting the consistency and accuracy of clinical decision-making. Existing automated tools often focus on general tumor segmentation and may not specifically address the nuanced clinical guidelines for VS measurement.

Methods

The core of this work is a two-stage deep learning framework for segmenting VS.

  • Stage 1 Segmentation: A 3D nnU-Net model is trained to segment the entire tumor (whole tumor segmentation). This stage is performed separately for T1-weighted (T1C) and T2-weighted (T2) MRI modalities.
  • Stage 2 Segmentation: A second nnU-Net model, building on the first stage, is trained to differentiate between the intra-meatal and extra-meatal portions of the tumor. This stage also uses modality-specific models. For post-operative scans, a fine-tuned Stage 1 model is used for whole tumor segmentation.

Following segmentation, a novel algorithm is employed to select the most relevant linear measurement to report. This algorithm considers:

  • The presence and size of the extra-meatal tumor portion.
  • Specific measurements like the maximum intrameatal diameter parallel to the posterior petrous pyramid, and maximum extrameatal diameters (both parallel and perpendicular).
  • A decision rule, incorporating these features, determines whether to report the maximum extrameatal diameter (DEM) or the maximum whole tumor diameter (DWT). For post-operative cases, the DWT is always reported.

Datasets

The study utilized data from three sources:

  • UCLH MC-RC Dataset: A multi-center dataset of 165 patients with unilateral VS, acquired between 2006 and 2019.
  • London SC-GK and Tilburg SC-GK Datasets: These single-center datasets comprise T1C and T2 MRI scans from patients undergoing Gamma Knife Stereotactic Radiosurgery (GK SRS). These were combined due to the limited availability of contrast-enhanced T1 modalities in the UCLH MC-RC dataset.
  • KCLH MC-RC Dataset: A retrospective dataset from King's College Hospital, London, consisting of 50 patients with unilateral VS, managed by a multidisciplinary skull base team. This dataset, comprising 187 MRI sessions (145 T1C, 42 T2), was used for the feature extraction and validation phase.

The paper does not introduce a new benchmark dataset but rather combines existing ones for training and uses the KCLH MC-RC dataset for evaluation.

Key Insights and Ideas

  • Clinical Guideline Replication: The primary innovation is the development of an automated system that not only segments tumors but also applies a decision-making logic to select the clinically relevant measurement, directly mirroring expert neuroradiologist practices and established guidelines.
  • Intra- vs. Extra-meatal Distinction: Accurately segmenting and differentiating the intra- and extra-meatal components is crucial for applying the correct measurement strategy, and the deep learning approach shows promise in achieving this.
  • Contextual Measurement Selection: The algorithm's ability to choose between DEM and DWT based on specific geometric features and tumor location (intracanalicular vs. extrameatal) is a significant step beyond simple volumetric or diameter measurements.
  • Potential for Standardization: By automating this process, the system offers a path towards more standardized and reproducible tumor measurements, reducing inter-observer variability.

Key Results

  • Segmentation Performance: The deep learning segmentation models achieved promising Dice scores:
  • T2 MRI: 0.8124 ± 0.2343 for extrameatal and 0.8969 ± 0.0521 for whole tumor regions.
  • T1 MRI: 0.8222 ± 0.2108 for extrameatal and 0.9049 ± 0.0646 for whole tumor regions.
  • Measurement Agreement: The automated measurements showed a strong correlation with manual measurements from an expert neuroradiologist (p < 0.0001) across different scenarios:
  • Pre-operative Extrameatal Tumors: High correlation (r = 0.9909) with a small bias (0.777 mm ± 1.057).
  • Pre-operative Intrameatal-only Tumors: Good correlation (r = 0.8693) with a bias of -0.069 mm ± 1.635.
  • Post-operative Tumors: Strong correlation (r = 0.9689) with a bias of 1.369 mm ± 2.614.
  • Clinical Utility: The system provides a visual guide and metrics, functioning as a clinical decision aid.

Limitations and Future Work

  • Over-segmentation: The authors acknowledge that over-segmentation by the deep learning model might lead to an overestimation of linear measurements, particularly in the pre-operative extrameatal and post-operative intrameatal regions.
  • Modality Differences: A slight difference in methodology (expert using T1C if available, automated preferring T2 if both available) might introduce biases in automated measurements.
  • Segmentation Failures: The algorithm did not provide acceptable segmentation for a small percentage of cases in both pre-operative and post-operative analyses.
  • Future Work: The authors suggest incorporating these features into formal reports to support multidisciplinary team meetings and adapting the framework for other benign brain tumors to extract tumor-specific features. Further work could also explore reducing over-segmentation and refining the modality selection strategy.

Summary updated

Abstract

Vestibular Schwannoma is a benign brain tumour that grows from one of the balance nerves. Patients may be treated by surgery, radiosurgery or with a conservative "wait-and-scan" strategy. Clinicians typically use manually extracted linear measurements to aid clinical decision making. This work aims to automate and improve this process by using deep learning based segmentation to extract relevant clinical features through computational algorithms. To the best of our knowledge, our study is the first to propose an automated approach to replicate local clinical guidelines. Our deep learning based segmentation provided Dice-scores of 0.8124 +- 0.2343 and 0.8969 +- 0.0521 for extrameatal and whole tumour regions respectively for T2 weighted MRI, whereas 0.8222 +- 0.2108 and 0.9049 +- 0.0646 were obtained for T1 weighted MRI. We propose a novel algorithm to choose and extract the most appropriate maximum linear measurement from the segmented regions based on the size of the extrameatal portion of the tumour. Using this tool, clinicians will be provided with a visual guide and related metrics relating to tumour progression that will function as a clinical decision aid. In this study, we utilize 187 scans obtained from 50 patients referred to a tertiary specialist neurosurgical service in the United Kingdom. The measurements extracted manually by an expert neuroradiologist indicated a significant correlation with the automated measurements (p < 0.0001).
BibTeX
@misc{wijethilake2023clinical,
  author = {Navodini Wijethilake and Steve Connor and Anna Oviedova and Rebecca Burger and Tom Vercauteren and Jonathan Shapey},
  title = {{A Clinical Guideline Driven Automated Linear Feature Extraction for Vestibular Schwannoma}},
  year = {2023},
  eprint = {2310.19392},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2310.19392},
}
Figure