[A case-control study of minimally invasive transforaminal interbody fusion with the assistance of robot and traditional fluoroscopy in the treatment of single-space lumbar disc herniation].

Haojie Chen, Xiaoqiang Huang, Lin Gao, Jianan Zhang, Shichang Liu, Chen Lin-na, Dingjun Hao, Zilong Zhang, Rui Qiao, Jiarui YangPubMed 2022 · DOI

Abstract

Compared with the traditional fluoroscopy-assisted MIS-TLIF, the spinal robot-assisted MIS-TLIF not only has more minimally invasive and safer, but also has higher accuracy in nail placement, lower incidence of upper articular process invasion, and more accurate decompression targets, which can be used for minimally invasive treatment of single-space lumbar disc herniation.
BibTeX
@inproceedings{chen2022case,
  author = {Haojie Chen and Xiaoqiang Huang and Lin Gao and Jianan Zhang and Shichang Liu and Chen Lin-na and Dingjun Hao and Zilong Zhang and Rui Qiao and Jiarui Yang},
  title = {{[A case-control study of minimally invasive transforaminal interbody fusion with the assistance of robot and traditional fluoroscopy in the treatment of single-space lumbar disc herniation].}},
  booktitle = {PubMed},
  year = {2022},
  doi = {10.12200/j.issn.1003-0034.2022.02.002},
}

Loading related content...

Figure