A Broadband/Resonant Approach to Axion Dark Matter Detection

Yonatan Kahn, Benjamin R. Safdi, Jesse ThalerarXiv 2016 · arXiv

Abstract

When ultralight axion dark matter encounters a static magnetic field, it sources an effective electric current that follows the magnetic field lines and oscillates at the axion Compton frequency. We propose a new experiment to detect this axion effective current. In the presence of axion dark matter, a large toroidal magnet will act like an oscillating current ring, whose induced magnetic flux can be measured by an external pickup loop inductively coupled to a SQUID magnetometer. We consider both resonant and broadband readout circuits and show that a broadband approach has advantages at small axion masses. We estimate the reach of this design, taking into account the irreducible sources of noise, and demonstrate potential sensitivity to axion dark matter with masses in the range of $10^{-14}$ eV to $10^{-6}$ eV. In particular, both the broadband and resonant strategies can probe the QCD axion with a GUT-scale decay constant.

Introduction: The Ultralight Axion Challenge

Axions are compelling dark matter candidates that also resolve the "Strong CP problem" in nuclear physics. Traditional detection methods, such as microwave cavity haloscopes (e.g., ADMX), rely on the conversion of axions into photons within a resonant cavity. However, these detectors are limited by a fundamental constraint: the cavity size must be comparable to the axion's de Broglie wavelength. For "ultralight" axions associated with Grand Unified Theories (GUTs), this wavelength can be kilometers long, making traditional resonant cavities impractical.

The proposed ABRACADABRA (A Broadband/Resonant Approach to Cosmic Axion Detection with an Amplifying B-field Ring Apparatus) experiment overcomes this "mass gap" by utilizing a non-resonant detection geometry that decouples the device size from the axion wavelength.

Experimental Design: The Toroidal Geometry

The core of the ABRACADABRA design is a superconducting toroidal magnet that generates a static magnetic field $B_0$. According to axion electrodynamics, the interaction between the axion field and this static magnetic field generates an effective oscillating electric current, $J_{eff} \propto g_{a\gamma\gamma} \dot{a} B_0$, where $g_{a\gamma\gamma}$ is the axion-photon coupling and $\dot{a}$ is the time derivative of the axion field.

Schematic of the ABRACADABRA detector geometry showing the toroidal magnet and the central region for the pickup loop.

As shown in the figure above, the static field is confined within the toroid. The effective current $J_{eff}$ flows along these field lines, effectively turning the toroid into an oscillating solenoid. This oscillating current generates a secondary magnetic field. A superconducting pickup loop is placed in the center of the toroid—a region where the static field $B_0$ is ideally zero. This isolation protects the sensitive SQUID (Superconducting Quantum Interference Device) magnetometer from the high-field environment, allowing it to detect the tiny flux changes induced by the axion field.

Readout Strategies: Broadband vs. Resonant

The experiment can operate in two distinct modes:

  1. Broadband Readout: The pickup loop is directly coupled to the SQUID. This allows for a simultaneous search across many orders of magnitude in axion mass, which is ideal for initial discovery.
  2. Resonant Readout: An LC circuit is used to enhance the signal at a specific frequency. While this increases sensitivity at that frequency, it requires scanning through different masses over time.

A key insight of the paper is that at very low axion masses (below $\sim 10^{-10}$ eV), the broadband approach can be more effective. This is because the axion's coherence time increases as its mass decreases, allowing for longer integration times that compensate for the lack of resonant enhancement.

Projected Sensitivity

The authors evaluated the potential reach of ABRACADABRA using standard dark matter density models and noise benchmarks for SQUID magnetometers.

Projected sensitivity to the axion-photon coupling $g_{a\gamma\gamma}$ as a function of axion mass $m_a$ for various detector configurations.

As illustrated in the sensitivity plot, a meter-scale detector ($V_B = 1 \text{ m}^3$) with a 5 Tesla field could probe axion masses from $10^{-14}$ eV to $10^{-6}$ eV. Crucially, the design is capable of reaching the "QCD axion band," potentially detecting axions with decay constants ($f_a$) at the GUT scale ($\sim 10^{16}$ GeV). This represents a significant improvement over existing constraints and fills the gap between high-mass haloscopes and low-mass NMR experiments like CASPEr.

Conclusion and Future Outlook

ABRACADABRA represents a paradigm shift in axion detection by moving away from wavelength-matched cavities. While the theoretical reach is promising, practical implementation will require rigorous magnetic shielding and vibration isolation to mitigate environmental noise. Future work involves developing small-scale prototypes to characterize these noise sources before scaling up to the full meter-scale apparatus required to explore the GUT-scale QCD axion.

Summary updated

Abstract

When ultralight axion dark matter encounters a static magnetic field, it sources an effective electric current that follows the magnetic field lines and oscillates at the axion Compton frequency. We propose a new experiment to detect this axion effective current. In the presence of axion dark matter, a large toroidal magnet will act like an oscillating current ring, whose induced magnetic flux can be measured by an external pickup loop inductively coupled to a SQUID magnetometer. We consider both resonant and broadband readout circuits and show that a broadband approach has advantages at small axion masses. We estimate the reach of this design, taking into account the irreducible sources of noise, and demonstrate potential sensitivity to axion dark matter with masses in the range of 10^{-14} eV to 10^{-6} eV. In particular, both the broadband and resonant strategies can probe the QCD axion with a GUT-scale decay constant.