Abstract
With the depletion of fossil energy, research on clean energy generation is developing rapidly. Though tidal phenomena contain a great deal of kinetic energy which can generate considerable power, few researches focus on configuration method of tidal generator in distribution network. In this paper, a bi-layer configuration method of tidal current turbine (TCT) in distribution network is proposed. The proposed method includes a TCT output simulation process which obtains the TCT output time-sequence curve based on historic data, and a bi-layer optimal configuration model which not only takes into account of the economics of both TCT and distribution network, but also considers the environment benefit. The configuration model is solved by using genetic algorithm and optimal power flow calculation. And, test results on IEEE 30-bus standard system verify the correctness and effectiveness of the proposed method.
1. Introduction
As the global energy landscape shifts toward renewable sources, tidal power has emerged as a promising candidate due to its high energy density and superior predictability compared to wind or solar energy. However, the integration of Tidal Current Turbines (TCTs) into existing electrical distribution networks presents significant challenges. Previous research has largely focused on turbine design or localized energy capture, often neglecting the systemic impact on the broader power grid.
This paper addresses the "configuration problem"—determining the optimal placement and quantity of TCTs to minimize costs while maximizing environmental gains. This requires balancing the high capital investment of tidal technology against operational savings, such as reduced network losses and lower emissions for the utility.
2. Methodology
2.1 TCT Output Simulation
To model the periodic nature of tides, an improved k-means clustering algorithm was applied to historical flow data from the Mile Point LB 20 tidal current station. By introducing "intensive degree" for initial cluster center selection and applying the "3σ rule" for outlier handling, the researchers generated realistic time-sequence curves for power output based on tidal velocity.
2.2 Bi-Layer Optimization Model
The core of the proposed method is a bi-layer optimization framework that separates long-term planning from short-term operational constraints.
- Upper Layer (Planning): This layer utilizes a Genetic Algorithm (GA) to determine the optimal location and number of TCT units. The objective function minimizes the annual comprehensive unit power generation cost, which includes investment, maintenance, network losses, and the economic benefits derived from reducing $CO_2$, $SO_2$, and $NO_x$ emissions.
- Lower Layer (Operation): Given a configuration from the upper layer, this layer solves the Optimal Power Flow (OPF) using a dual interior point method. It adjusts the output of conventional gas turbines to ensure economic grid operation within voltage limits.
2.3 Solution Algorithm
The interaction between these layers is iterative. The upper layer proposes a configuration, and the lower layer evaluates its operational feasibility and cost, feeding this information back to the GA to refine the next generation of solutions.
3. Results and Discussion
The method was tested on the IEEE 30-bus standard system across three scenarios to evaluate the impact of environmental considerations:
- Scenario 1 (TCT + Environmental Benefits): This scenario resulted in the highest TCT integration. Conventional gas turbine output dropped by 35%, and total system power generation increased by 49%. The comprehensive cost was calculated at -26.40 dollars, indicating that the environmental and operational savings outweighed the investment costs.
- Scenario 2 (No TCT): This baseline scenario yielded a positive cost of 5.09 dollars.
- Scenario 3 (TCT without Environmental Benefits): Without accounting for emission reductions, fewer TCTs were installed, and the comprehensive cost rose to 12.53 dollars.
These results demonstrate that while TCTs require significant capital, their inclusion becomes highly favorable when environmental benefits are monetized. In Scenario 1, the "negative cost" phenomenon highlights how avoided emission penalties and fuel savings can transform tidal energy into a net economic benefit.
4. Conclusion
This paper presents a robust bi-layer framework for integrating tidal energy into distribution networks. By leveraging the predictability of tides and incorporating environmental externalities into the economic model, the proposed method provides a clear pathway for utility planning. Future work will explore the integration of energy storage systems to mitigate tidal "valley" periods and investigate wake effects in large-scale turbine arrays to further refine the optimization model.
Summary updated