Abstract
Intracoronary optical coherence tomography (OCT) is a powerful tool for identifying high-risk coronary plaques and monitoring treatment effects. However, its clinical utility is limited by the time-intensive nature of manual analysis and the prevalence of image artifacts. We developed AutoOCT, a modular deep learning framework that incorporates artifact correction to automate plaque composition analysis. Validated against histology and external clinical trial data (IBIS-4 and CLIMA), AutoOCT achieved 83% classification accuracy and successfully replicated core laboratory findings regarding drug-induced plaque stabilization and MACE risk prediction.
Introduction
Intracoronary OCT provides near-microscopic resolution of coronary arteries, enabling the identification of "vulnerable" plaques—such as thin-cap fibroatheromas (TCFA)—that are prone to causing major adverse cardiovascular events (MACE). Despite its potential, a single patient pullback generates thousands of frames, making manual analysis by expert clinicians or core laboratories slow and subjective. Furthermore, real-world OCT images are often degraded by artifacts like blood interference or guidewire shadows. While AI-based solutions have been proposed, many fail in clinical settings because they are trained on idealized, artifact-free datasets. We sought to determine if an artifact-corrected AI system could robustly identify plaque changes and predict clinical outcomes.
Methods
AutoOCT was developed using a DeepLabv3+ architecture for image segmentation and an EfficientNet architecture for plaque classification. The system was trained on 36,212 unselected OCT frames from 106 patients, ensuring exposure to real-world data variability. A novel pre-processing module using histogram matching was implemented to correct common artifacts. The pipeline automatically segments the lumen, calcium, lipid deposits, and fibrous caps, while also detecting stents and guide catheters.
Results
AutoOCT demonstrated high performance across multiple validation benchmarks. In a head-to-head comparison with co-registered histopathology, the system achieved 83% accuracy in plaque classification, performing non-inferiorly to expert human readers.
External validation using the IBIS-4 study confirmed that AutoOCT could detect the "signature" of plaque healing following high-intensity statin therapy, showing a significant increase in minimum fibrous cap thickness (FCT) from 62.9µm to 81.8µm. Additionally, using data from the CLIMA study, AutoOCT identified high-risk features (e.g., lumen area <3.5 mm², FCT <75µm) that predict 1-year MACE with accuracy comparable to specialized core laboratories.
Discussion
The development of AutoOCT addresses the primary bottlenecks in intracoronary OCT analysis: speed, subjectivity, and image quality. By processing full pullbacks in 3–5 minutes and handling "messy" clinical data, this AI framework enables rapid, reproducible assessment of plaque stabilization and vulnerability. While currently intended to augment expert analysis, AutoOCT's performance suggests it could soon assist in real-time clinical decision-making during catheterization procedures, facilitating personalized management of coronary artery disease.
References 1. Raber L, et al. JACC Cardiovasc Imaging. 2019;12:1518-1528. 2. Prati F, et al. Eur Heart J. 2020;41:383-391. 3. Jessney B, et al. Cardiovasc Revasc Med. 2024.
- Tearney GJ, et al. J Am Coll Cardiol. 2012;59:1058-72.
Summary updated