3D Imaging via Four PMUT Receivers by Compressed Sensing

Nikita G. Lukhanin, Divij Muthu, Chaoying Gu, Megan Teng, Kamyar Behrouzi, Chunming Chen, Laura Waller, Liwei Lin2026

Abstract

We have successfully demonstrated three-dimensional (3D) ultrasound imaging via compressed sensing using piezoelectric micromachined ultrasonic transducers (pMUTs). This work reports the first experimental demonstration of compressed sensing with pMUTs, achieving 3D image reconstruction near the acoustic wavelength limit by only four receiving elements. Pseudo-random transmission signatures were encoded through frequency and delay modulation to enable high-fidelity reconstruction with a peak signal contrast of 28.7 dB. A 16-element lithium-niobate pMUT array operating at a resonant frequency of 50.4 kHz was used, with each element generating up to 120 dB sound pressure at 10 mm. Compared to the conventional scheme using beamforming approaches for 3D imaging that require a large array of transducers and complex electronics, this compressed sensing scheme significantly reduces hardware complexity, power consumption, and data acquisition. As such, this new class of pMUT-based imaging establishes a pathway toward low-cost, scalable 3D ultrasound perception for robotics, wearable electronics, autonomous navigation, and medical diagnostics.
BibTeX
@misc{lukhanin2026d,
  author = {Nikita G. Lukhanin and Divij Muthu and Chaoying Gu and Megan Teng and Kamyar Behrouzi and Chunming Chen and Laura Waller and Liwei Lin},
  title = {{3D Imaging via Four PMUT Receivers by Compressed Sensing}},
  year = {2026},
  doi = {10.1109/mems64181.2026.11419480},
}

Loading related content...

Figure