315 The application of TMD changing the damping capacity to a high-rise building

Yukihiro Shimano, Takeshi Katayama, Toshiyuki Tanaka, M. Yamamoto, Satoru AizawaThe Proceedings of the Symposium on the Motion and Vibration Control 2001

Abstract

This paper described the application of TMD changing the damping capacity to a high-rise building in Osaka, which uses the upper stories as hotel. The TMD has been used a new type of oil-damper. This damper can change the damping capacity by switching of the electromagnetic valve. It is usually set at the optimum damping factor to operate as normal TMD to reduce wind-induced motion of the building. When large earthquakes strike, it automatically switches the valve to high-damping mode to keep the displacement of ice thermal storage tanks, used as moving mass, within the stroke limit. To investigate the vibration control performance when subjected to large earthquake, a parametric study was performed. The study proved that its performance will be improved by utilizing the TMD which has optimum period, optimum damping and larger mass ratio, in case that a large stroke and a large stroke velocity of damper are permitted.
BibTeX
@inproceedings{shimano2001application,
  author = {Yukihiro Shimano and Takeshi Katayama and Toshiyuki Tanaka and M. Yamamoto and Satoru Aizawa},
  title = {{315 The application of TMD changing the damping capacity to a high-rise building}},
  booktitle = {The Proceedings of the Symposium on the Motion and Vibration Control},
  year = {2001},
  doi = {10.1299/jsmemovic.2001.7.395},
}