2D spectral-temporal fitting of synthetic fMRS data improves the precision of fitted glutamate temporal dynamics parameters three-fold
Abstract
It has been suggested that fitting dynamic MRS data in tandem (2D fitting) should be more precise than conventional 1D fitting, without impairing its accuracy. Functional MRS (fMRS) is a dynamic method used for detecting endogenous metabolic changes in the brain. In this work, we implemented a 2D spectral-temporal fitting framework for the synthetic fMRS data. Preliminary experiments confirm that 2D fitting improves precision approximately three-fold compared to the conventional 1D fitting in terms of fMRS data.
BibTeX
@inproceedings{liu2024d,
author = {Yiling Liu and Zhiyong Zhang and Assaf Tal},
title = {{2D spectral-temporal fitting of synthetic fMRS data improves the precision of fitted glutamate temporal dynamics parameters three-fold}},
booktitle = {Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition},
year = {2024},
doi = {10.58530/2023/3942},
}Ask Althea to put this paper to the test.