1375 NOVEL, REMOTELY-CONTROLLED, ARTIFICIAL URINARY SPHINCTER: A RETRO-COMPATIBLE DEVICE

Jacques Corcos, Sami Hached, Oleg Loutochin, Mohamad SawanThe Journal of Urology 2013

Abstract

You have accessJournal of UrologyUrodynamics/Incontinence/Female Urology: Incontinence, Evaluation & Therapy (III)1 Apr 20131375 NOVEL, REMOTELY-CONTROLLED, ARTIFICIAL URINARY SPHINCTER: A RETRO-COMPATIBLE DEVICE Jacques Corcos, Sami Hached, Oleg Loutochin, and Mohamad Sawan Jacques CorcosJacques Corcos Montreal, Canada More articles by this author , Sami HachedSami Hached Montreal, Canada More articles by this author , Oleg LoutochinOleg Loutochin Montreal, Canada More articles by this author , and Mohamad SawanMohamad Sawan Montreal, Canada More articles by this author View All Author Informationhttps://doi.org/10.1016/j.juro.2013.02.2729AboutPDF ToolsAdd to favoritesDownload CitationsTrack CitationsPermissionsReprints ShareFacebookTwitterLinked InEmail INTRODUCTION AND OBJECTIVES The implantation of an artificial urinary sphincter (AUS) is considered the standard treatment for severe cases of stress urinary incontinence in men. The functioning of this implant is purely hydro-mechanical applying a constant pressure around bulbous urethra. Common reasons for revision of the device are insufficient cuff pressure or at contrary urethral atrophy secondary to this constant pressure. Furthermore its functioning requires some dexterity limiting its use in some patients. Our objective was to develop a novel AUS offering the possibility to remotely control the pressure within the implant rapidly and without complex manipulation. METHODS We developed this new sphincter using an AMS 800 to which we replace the pump. The new electronic pump has been designed as small as possible to facilitate its implantation beside the reservoir and to be compatible with the existing AMS 800 tubing, cuff and balloon. We integrated a minimal number of components to minimize power consumption and reduce failure risk and production cost. RESULTS The device is extremely compact and totally wireless (Fig.1) It can be checked and updated remotely. The implants are fast-reacting and compatible with many Bluetooth remote controllers. The prototype has been tested on a fresh pig's bladder (Fig.2A, B) and total continence was proven (Fig.2C). CONCLUSIONS The new device can be easily implanted in patients with limited dexterity and also in women. The new electronic pump could also replace a manual pump in an already implanted device. © 2013 by American Urological Association Education and Research, Inc.FiguresReferencesRelatedDetails Volume 189Issue 4SApril 2013Page: e562 Advertisement Copyright & Permissions© 2013 by American Urological Association Education and Research, Inc.MetricsAuthor Information Jacques Corcos Montreal, Canada More articles by this author Sami Hached Montreal, Canada More articles by this author Oleg Loutochin Montreal, Canada More articles by this author Mohamad Sawan Montreal, Canada More articles by this author Expand All Advertisement Advertisement PDF downloadLoading ...
BibTeX
@article{corcos2013novel,
  author = {Jacques Corcos and Sami Hached and Oleg Loutochin and Mohamad Sawan},
  title = {{1375 NOVEL, REMOTELY-CONTROLLED, ARTIFICIAL URINARY SPHINCTER: A RETRO-COMPATIBLE DEVICE}},
  journal = {The Journal of Urology},
  year = {2013},
  doi = {10.1016/j.juro.2013.02.2729},
}

Loading related content...

Figure