Abstract
As a new type of retaining structure, Gabion reinforced retaining walls have seen increasing application in China. However, current research primarily focuses on ground motion loads (seismic), with less attention paid to environmental vibration loads, such as those from industrial equipment. This study investigates the spatial distribution of dynamic response and vibration energy in multistage lattice reinforced soil retaining walls under cyclic dynamic loads through laboratory model tests. The results indicate that dynamic strain attenuation is concentrated in the upper retaining walls, while dynamic earth pressure attenuation occurs primarily within 10 meters of the power source. Furthermore, both dynamic strain and acceleration amplitudes increase significantly with equipment operating frequency.
Introduction
Gabion reinforced retaining walls—stone-filled wire cages combined with geogrids—are favored for their ecological benefits and economic efficiency. While their performance under seismic conditions is well-documented, their behavior under "environmental" or "operational" cyclic loads (e.g., nearby machinery or construction equipment) remains a critical knowledge gap. Engineers require a clear understanding of how vibration energy propagates through these multistage systems to prevent structural failure or excessive deformation under constant industrial activity.
Methodology
Researchers conducted a laboratory model test using a 1:30 geometric similarity ratio, modeled after a mine slope project in Fengxin, Jiangxi Province.
- Similarity Theory: The Buckingham $\pi$ theorem was employed to derive similarity constants for physical quantities, ensuring the small-scale model accurately reflected the prototype's behavior.
- Construction: The model utilized a 7-layer filling method with silty clay backfill (density: $1.82\text{g/cm}^3$, compression modulus: $7.04\text{ MPa}$).
- Instrumentation: The setup included strain gauges on the geogrids, earth pressure cells, and accelerometers to map the dynamic response across the structure.
- Loading: Sinusoidal cyclic loads of 5kN and 6kN were applied at frequencies of 3, 6, 9, 12, and 15Hz to simulate various mechanical operating modes.
Key Insights and Results
Dynamic Strain and the "Middle-Peak" Phenomenon
Experimental data revealed that dynamic strain in the geogrids follows a unimodal or bimodal distribution. The highest stress levels typically appear in the middle of each retaining wall level, identifying these points as critical for structural monitoring. As shown in the strain profiles, the amplitude of these responses is highly sensitive to frequency, increasing markedly as the load frequency rises from 3Hz to 15Hz.
Spatial Attenuation of Vibration Energy
Vibration energy does not penetrate the structure uniformly. Attenuation is most aggressive in the second and third walls from the bottom. The lowest wall exhibits less attenuation because it is constrained by the foundation, limiting its energy dissipation through movement. For dynamic earth pressure, the primary bearing range is within 10 meters of the power source, beyond which pressure drops by up to 62.6%.
Acceleration Response
Acceleration tends to decay along vertical lines. Due to the high rigidity and integrity of the reinforced body, the attenuation rate is highest at the surface and slows as vibrations move deeper into the secondary wall structures. Despite these vibrations, the peak amplitude of dynamic strain remained relatively small, suggesting the reinforced soil structure is effective at mitigating dynamic stress on the foundation bed.
Conclusion and Future Work
The study confirms that multistage Gabion walls are sensitive to the frequency of cyclic loads, with higher frequencies posing a greater risk to stability. While the reinforced structure effectively manages stress, specific attention must be paid to the joints between retaining walls, where earth pressure drops can lead to soil displacement. Future research should address long-term fatigue of the Gabion wire and geogrids under millions of cycles, as well as potential deviations in 1g laboratory modeling compared to full-scale field conditions.
Summary updated