Single-shot diffraction data from the Mimivirus particle using an X-ray free-electron laser

Tomas Ekeberg, Martin Svenda, M. Seibert, Chantal Abergel, Filipe R. N. C. Maia, Virginie Seltzer, Daniel P. DePonte, Andrew Aquila, Jakob Andreasson, Bianca Iwan, H. Olof Jönsson, Daniel Westphal, Duško Odić, Inger Andersson, Anton Barty, Meng Liang, Andrew V. Martin, Lars Gumprecht, Holger Fleckenstein, S. Bajt, Miriam Barthelmeß, N. Coppola, Jean‐Michel Claverie, N. Duane Loh, Christoph Bostedt, John D. Bozek, J. Krzywiński, M. Messerschmidt, Michael J. Bogan, Christina Y. Hampton, Raymond G. Sierra, Matthias Frank, Robert L. Shoeman, Lukas Lomb, L. Foucar, Sascha W. Epp, Daniel Rolles, Artem Rudenko, Robert Hartmann, Andreas Hartmann, Nils Kimmel, P. Holl, G. Weidenspointner, Benedikt Rudek, Benjamin Erk, Stephan Kassemeyer, I. Schlichting, Lothar Strüder, J. Ullrich, Carlo Schmidt, Faton Krasniqi, Günter Hauser, Christian Reich, H. Soltau, Sebastian Schorb, H. Hirsemann, C. Wunderer, H. Graafsma, Henry N. Chapman, János HajduScientific 2016 · DOI · OpenAlex

Abstract

Free-electron lasers (FEL) hold the potential to revolutionize structural biology by producing X-ray pulses short enough to outrun radiation damage, thus allowing imaging of biological samples without the limitation from radiation damage. Thus, a major part of the scientific case for the first FELs was three-dimensional (3D) reconstruction of non-crystalline biological objects. In a recent publication we demonstrated the first 3D reconstruction of a biological object from an X-ray FEL using this technique. The sample was the giant Mimivirus, which is one of the largest known viruses with a diameter of 450 nm. Here we present the dataset used for this successful reconstruction. Data-analysis methods for single-particle imaging at FELs are undergoing heavy development but data collection relies on very limited time available through a highly competitive proposal process. This dataset provides experimental data to the entire community and could boost algorithm development and provide a benchmark dataset for new algorithms.

Introduction: The Challenge of Single-Particle Imaging

Determining the 3D structure of biological molecules typically relies on cryo-electron microscopy (cryo-EM) or X-ray crystallography. However, these methods have limitations: crystallization is often difficult, and freezing can alter native structures. X-ray free-electron lasers (FELs) offer a compelling alternative through single-particle imaging.

By utilizing femtosecond X-ray pulses, researchers can capture diffraction data from a single, non-crystalline particle before it is destroyed by radiation—a concept known as "diffraction-before-destruction." The primary hurdle is computational: particles are injected into the beam in random orientations, requiring thousands of 2D snapshots to be "stitched" into a 3D volume. Access to high-quality experimental data is essential for developing the algorithms needed to solve this orientation problem.

Methods and Experimental Setup

The study was conducted at the Linac Coherent Light Source (LCLS) using the Atomic Molecular Optics (AMO) beamline. Purified Mimivirus particles, chosen for their large size (approx. 450 nm) and strong diffraction signal, were aerosolized and guided into the X-ray beam.

Data was captured using a pair of pnCCD detectors at a rate of 60 Hz. The X-ray pulses were approximately 70 fs long with a photon energy of 1.2 keV. To identify "hits" among millions of frames, the team employed an on-line hit-identification strategy based on pixel intensity thresholds. The final 3D structure was recovered using a modified Expand, Maximize, and Compress (EMC) algorithm.

The Mimivirus Dataset

The authors have released two versions of the data through the Coherent X-ray Imaging Data Bank (CXIDB). The Full Record includes 19 LCLS runs (14 sample runs and 5 "dark" runs for background calibration), providing the raw experimental output including noise and misses. The Filtered Dataset consists of 198 high-quality, unsaturated diffraction patterns used for the published 3D reconstruction.

Table summarizing the data collection runs, including total frames and those selected for final 3D reconstruction.

Results and Key Insights

The dataset enabled a 3D reconstruction with a full-period resolution of 125 nm. This proof-of-concept demonstrates that 70 fs pulses are sufficiently short to "outrun" radiation damage.

A selection of 2D diffraction patterns captured from single Mimivirus particles, showing the characteristic rings and streaks used for orientation.

The experiment highlighted the "needle-in-a-haystack" challenge of FEL imaging, with a hit rate of only about 0.3%. The 198 patterns in the filtered set were selected from 1,600 initial hits, specifically excluding those with detector saturation. Validation was performed using Fourier Shell Correlation (FSC), splitting the data into two independent halves to ensure the reconstruction was not an algorithmic artifact.

Conclusion and Future Outlook

While the current resolution of 125 nm is limited by photon energy and detector geometry, this landmark dataset serves as a vital benchmark. Future work will leverage higher-energy X-rays and faster detectors to push toward atomic-scale imaging. By providing this data openly, the authors aim to accelerate the development of machine-learning and manifold-based approaches to solve the complex orientation challenges inherent in single-particle FEL experiments.

Summary updated

Abstract

Free-electron lasers (FEL) hold the potential to revolutionize structural biology by producing X-ray pules short enough to outrun radiation damage, thus allowing imaging of biological samples without the limitation from radiation damage. Thus, a major part of the scientific case for the first FELs was three-dimensional (3D) reconstruction of non-crystalline biological objects. In a recent publication we demonstrated the first 3D reconstruction of a biological object from an X-ray FEL using this technique. The sample was the giant Mimivirus, which is one of the largest known viruses with a diameter of 450 nm. Here we present the dataset used for this successful reconstruction. Data-analysis methods for single-particle imaging at FELs are undergoing heavy development but data collection relies on very limited time available through a highly competitive proposal process. This dataset provides experimental data to the entire community and could boost algorithm development and provide a benchmark dataset for new algorithms.
BibTeX
@inproceedings{ekeberg2016single,
  author = {Tomas Ekeberg and Martin Svenda and M. Seibert and Chantal Abergel and Filipe R. N. C. Maia and Virginie Seltzer and Daniel P. DePonte and Andrew Aquila and Jakob Andreasson and Bianca Iwan and H. Olof Jönsson and Daniel Westphal and Duško Odić and Inger Andersson and Anton Barty and Meng Liang and Andrew V. Martin and Lars Gumprecht and Holger Fleckenstein and S. Bajt and Miriam Barthelmeß and N. Coppola and Jean‐Michel Claverie and N. Duane Loh and Christoph Bostedt and John D. Bozek and J. Krzywiński and M. Messerschmidt and Michael J. Bogan and Christina Y. Hampton and Raymond G. Sierra and Matthias Frank and Robert L. Shoeman and Lukas Lomb and L. Foucar and Sascha W. Epp and Daniel Rolles and Artem Rudenko and Robert Hartmann and Andreas Hartmann and Nils Kimmel and P. Holl and G. Weidenspointner and Benedikt Rudek and Benjamin Erk and Stephan Kassemeyer and I. Schlichting and Lothar Strüder and J. Ullrich and Carlo Schmidt and Faton Krasniqi and Günter Hauser and Christian Reich and H. Soltau and Sebastian Schorb and H. Hirsemann and C. Wunderer and H. Graafsma and Henry N. Chapman and János Hajdu},
  title = {{Single-shot diffraction data from the Mimivirus particle using an X-ray free-electron laser}},
  booktitle = {Scientific},
  year = {2016},
  doi = {10.1038/sdata.2016.60},
}
Figure