Monitoring of the UHPFRC strengthened Chillon viaduct under environmental and operational variability
Lists
Only you see this
Abstract
Datasets corresponding to 3 months of data of the monitoring of Chillon viaduct. Each file contains: the vibration data from 11 acelerometers, in vertical direction the sampling ratio Temperature Humidity The accelerometer positions are illustarted in the pdf "accelerometres Position.pdf". When employing this dataset, please cite:"Martín-Sanz, Henar, Konstantinos Tatsis, Vasilis K. Dertimanis, Luis David Avendaño-Valencia, Eugen Brühwiler, and Eleni Chatzi. "Monitoring of the UHPFRC strengthened Chillon viaduct under environmental and operational variability." <em>Structure and Infrastructure Engineering</em> (2019): 1-31."
BibTeX
@inproceedings{garcia2019monitoring,
author = {Henar Martín-Sanz García and Konstantinos Tatsis and Vasilis Dertimanis and Luis David Avendaño-Valencia and Eugen Brühwiler and Eleni Chatzi},
title = {{Monitoring of the UHPFRC strengthened Chillon viaduct under environmental and operational variability}},
booktitle = {Zenodo},
year = {2019},
doi = {10.5281/zenodo.3234804},
}Loading related content...