Iconic Retrieval by Contents from Databases of Cardiological Sequences

Gianfranco Congiu, Alberto Del Bimbo, Enrico VicarioOpenalex Unknown 1995 · OpenAlex

Abstract

The inherent complexity of retrieval by contents of image sequences imposes the use of appropriate techniques supporting the representation of the contents and the specification of content-oriented queries. A number of such techniques have been proposed in the literature but all of these consider images representing un-deformable rigid shapes. In this paper, the case of time-varying imaged curves is addressed with reference to a database of cineangiographic reports. Qualitative static and dynamic shape descriptors are introduced to provide a symbolic representation of the evolution of deformable shapes, and a language based on Interval Logic is presented which supports the expression of content-oriented queries. A prototype system is described which exploits these indexing and querying languages to support retrieval by contents from a database of cineangiographic reports through visual iconic interaction.

Introduction

In the mid-90s, the explosion of multimedia data created a massive bottleneck: how to find a specific video clip without manually watching everything? While researchers had developed "iconic retrieval" (using visual symbols to index images), most systems only worked for rigid, unchanging objects. Medical imaging—specifically cineangiography (X-ray videos of the heart)—presents a much tougher challenge. The heart wall is a "time-varying curve" that constantly deforms. A doctor might want to find all patients who exhibit an "outward motion in the apical region during the systolic phase" (a sign of pathology). Traditional text-based keywords are too imprecise to capture these complex geometric and temporal nuances.

This paper introduces a symbolic framework for retrieving medical image sequences based on the motion of deformable shapes. By combining "codon-based" shape descriptors with temporal Interval Logic, the authors created a prototype system that allows doctors to search for specific cardiac pathologies using a visual, iconic interface.

Methods

The authors propose a "dual language" approach: one for describing the raw data (concrete) and one for asking questions (abstract).

Static Curve Description (The "Codon" Approach)

Instead of storing raw coordinates, the system breaks a heart wall contour into a chain of "codons." A codon is a sub-curve defined by the minima of its bending function. Each codon is assigned symbolic attributes: type, symmetry, bending (how sharp it is), and extension (width). This makes the description invariant to zooming or rotation.

Heart wall contour segmentation

As shown in the figure above, the heart wall is segmented into discrete parts. These parts are then classified into a library of symbolic shapes.

Codon types and curvature graphs

The figure above illustrates the different codon types ([0+], [0-], [1+], [1-], [2-]) and their corresponding curvature graphs, which form the basis of the symbolic representation.

Dynamic Tracking and Attributes

To handle motion, the system tracks these codons across frames (time samples). They use a cost-minimization function to link a "parent" codon in frame $j$ to its "child" in frame $j+1$, even if the codon splits or merges. Two key features are added to the temporal sequence:

  • Straining: Whether a section of the heart is expanding, contracting, or stable.
  • Region: Mapping the codon to anatomical areas (anterior, apical, or inferior).

Temporal Querying via Interval Logic

The system uses Allen’s Interval Logic, which defines 13 possible relationships between time intervals (e.g., "before," "overlaps," "during"). Users don't write code; they arrange icons representing shape and motion on a timeline to build a query through a visual iconic interface.

Datasets

The system was tested on a database of cineangiographic reports. Each report consists of a sequence of images (14–28 samples) covering a full heart-beating period. The contours were extracted using a semi-automatic process involving edge detection and manual marking by medical personnel. The prototype was implemented on an IBM R6000 workstation.

Key Insights and Results

  • Symbolic over Numerical: For retrieval, perfect pixel coordinates are unnecessary. By converting geometry into symbolic "codons," the system becomes robust to the noise and variability inherent in medical imaging.
  • Deformation as a Searchable Feature: By treating "straining" (expansion/contraction) as a primary attribute, the authors moved beyond simple motion tracking to true deformation analysis.
  • Pathology Retrieval: The system could identify "dyskinetic" segments—parts of the heart wall that move outward when they should be contracting—by searching for an "expansive strain" during the "systolic phase."
  • Query Refinement: A broad search (e.g., any expansion in the apical region) can be iteratively refined by adding more temporal constraints (e.g., adding a requirement for contraction during the diastolic phase), effectively narrowing down the results to a specific subset of patients.

Limitations and Future Work

The system relies on a "semi-automatic" process to extract contours, which required significant manual effort in the 1990s. Modern deep learning would likely automate this today. Additionally, the study focuses on 2D planar curves; extending this to 3D volumetric data (like modern MRI or CT) would require a significantly more complex "codon" equivalent for surfaces. While the logic is sound, the paper does not discuss how the model-checking algorithm scales as the database grows to thousands or millions of reports.

The authors conclude that while they focused on cardiology, this "dual language" framework for time-varying curves is general enough to be applied to any field dealing with non-rigid motion, from fluid dynamics to meteorology.

Summary updated

BibTeX
@inproceedings{congiu1995iconic,
  author = {Gianfranco Congiu and Alberto Del Bimbo and Enrico Vicario},
  title = {{Iconic Retrieval by Contents from Databases of Cardiological Sequences}},
  booktitle = {Openalex Unknown},
  year = {1995},
  doi = {10.1007/978-0-387-34905-3\_10},
}

Loading related content...

Figure