Abstract
This document provides formal corrections to the article by Daurer et al. [IUCrJ (2017). 4, 251–262]. It rectifies mathematical errors in the fundamental scattering equations and updates photon intensity values in the results table to ensure the accuracy of the experimental model for bioparticle imaging.
Introduction: Addressing Errors in XFEL Imaging Models
In the original 2017 study, Daurer et al. investigated experimental strategies for "diffraction before destruction." This technique utilizes femtosecond X-ray pulses from X-ray Free-Electron Lasers (XFELs) to capture diffraction patterns from biological samples, such as viruses, before radiation damage occurs.
Post-publication review revealed critical mathematical errors in the equations describing scattering intensity and the scattering vector. This corrigendum serves to correct these foundational formulas, which are essential for researchers performing X-ray diffraction simulations or analyzing experimental data.
Mathematical Corrections
The corrections focus on the mathematical framework used to model how X-rays interact with spherical bioparticles. In X-ray imaging, small constants (like a factor of 2 or 3) in an equation can lead to significant discrepancies when scaling experimental data to theoretical models. Correcting these ensures the physical model aligns with the observed diffraction physics.
Scattering Intensity
The formula for scattering intensity ($I_i$) in Equation (1) was corrected by removing an erroneous denominator of ‘3’. The updated equation is:
$$I_i = I^0 QE \left( \frac{\pi^2 d^3 |\Delta n| \Delta x}{D \lambda^2} \right)^2 \left| \frac{\sin(s_i) - s_i \cos(s_i)}{s_i^3} \right|^2$$
Scattering Parameter
The definition of the scattering parameter ($s_i$) in Equation (2) was corrected by removing an extra factor of ‘2’. The updated definition is:
$$s_i = \pi d |q_i|$$
These parameters are vital for calculating how X-rays interact with a spherical particle (like a virus) and how that interaction translates into the recorded diffraction pattern.
Data Integrity and Updated Results
Beyond the mathematical formulas, this corrigendum updates specific values in Table 1, which summarizes photon intensity metrics.
- Maximum Photon Intensity: The value in the final row was revised downward from 0.41 to 0.25.
- Standard Deviation: The associated standard deviation was corrected from 0.05 to 0.03.
These revisions indicate that the original reported intensities were slightly overestimated. Such distinctions are critical for researchers calculating signal-to-noise ratios or determining detector requirements for future experiments.
Conclusion
This corrigendum ensures that the physical models used in bioparticle imaging align correctly with observed diffraction physics. It is strictly a formal amendment to the existing scientific record to maintain the accuracy of the published methodology. Researchers are advised to use these updated equations and values for any subsequent work involving Omono River virus (OmRV) imaging or similar diffraction studies.
Summary updated