Enhancing Tumor Microstructural Quantification With Machine Learning and Diffusion‐Relaxation <scp>MRI</scp>
Abstract
Diffusion MRI (dMRI) enables tumor characterization, providing metrics of cellular properties that could become powerful biomarkers.1-3 However, the number and type of properties that can be resolved depends on the number of images encompassing the dMRI protocol. Long acquisition times are often required to support accurate microstructural signal models, implying that these often remain relegated to research studies. Here, we investigated whether machine learning (ML) can bridge the gap between routine, clinical dMRI and more advanced quantitative methods, such as joint diffusion-relaxation (DR) imaging. We studied the ML-based prediction of advanced DR parametric maps from short dMRI protocols that are feasible in the clinic, focusing on pelvic and abdominal imaging of advanced solid tumors. Complete methods in Data S1. Data from two scanners were analyzed (1.5T Siemens Avanto; 3T GE SIGNA Pioneer), which included anatomical T2w and DR imaging (21 contrasts: 7 b-values acquired at 3 TE each). To simulate a more clinical protocol, we extracted a subset of five images (the five lowest b-values acquired at the minimum TE, referred to as “clinical protocol”). Conversely, the full set of 21 DR measurements is referred to as “advanced protocol.” DR images were denoised and corrected for Gibbs ringing and motion. Tumors >1 cm in diameter were manually segmented on the T2w scan and co-registered to DR space. Biopsies from one of the imaged tumors were also collected. From the clinical protocol, we fitted a mono-exponential signal decay S = S 0 e − bADC $$ S={S}_0{e}^{- bADC} $$ on three scenarios: 1) the whole dMRI clinical set of images, obtaining the Apparent Diffusion Coefficient (ADC) and the proton density S0; 2) the lowest b-values (0, 50, 100 s/mm2), obtaining a vascular-driven pseudo-ADC (ADCfast); 3) the highest b-values (100, 400, 900 s/mm2), obtaining an average, tissue ADC (ADCslow). Moreover, a proxy for the vascular, pseudo-diffusion signal fraction was obtained by combining the S0 estimates from the first and last fits as F ≈ 1 − S 0 , slow S 0 $$ F\approx 1-\frac{S_{0,\mathrm{slow}}}{S_0} $$ . The advanced protocol was taken as reference. It enables fitting a complex signal model, jointly capturing T2 relaxation, intravoxel incoherent motion (IVIM) and tissue diffusion, distinguishing between Gaussian/non-Gaussian diffusion. The used DR signal representation will be referred as T2-IVIM-Kurtosis and is: S = S 0 fe − b D v − TE T 2 v + 1 − f e − b D t + 1 6 K b D t 2 − TE T 2 t $$ S={S}_0\left({fe}^{-b{D}_v-\frac{TE}{T2v}}+\left(1-f\right){e}^{-b{D}_t+\frac{1}{6}K{\left(b{D}_t\right)}^2-\frac{TE}{T2t}}\right) $$ ( v / t $$ v/t $$ indicate vascular/tissue properties). We studied two predictions strategies (Fig. 1a): 1) signal-to-signal predicts the DR signals of the advanced protocol given the clinical protocol, so that T2-IVIM-Kurtosis can be fitted on such predicted signals; 2) maps-to-maps predicts directly T2-IVIM-Kurtosis metrics from ADCfast, ADCslow, F. Both approaches were implemented using seven algorithms and deployed on a leave-one-out fashion. 6/7 algorithms worked voxel-wise, while one patch-wise.4 All implementations are freely available online (https://github.com/carlosmacarro/clinical2advanced). We assessed the quality of the predicted T2-IVIM-Kurtosis metrics through per-patient bias and dispersion indices (BI, DI), with BI = P 50 E $$ \mathrm{BI}={P}_{50}(E) $$ and DI = P 75 E − P 25 E $$ \mathrm{DI}=\left({P}_{75}(E)-{P}_{25}(E)\right) $$ , where P X $$ {P}_X $$ is the X $$ X $$ th percentile and E = prediction − ground truth ground truth $$ E=\frac{\mathrm{prediction}-\mathrm{ground}\ \mathrm{truth}}{\mathrm{ground}\ \mathrm{truth}} $$ the relative error. Pixel-level correlations between reference/estimated parameters were also computed. We assessed the impact of the training set size on the prediction by systematically reducing the number of patients included in the training set. Thirty-two patients with advanced solid tumors (Fig. S1 in the Supplemental Material) were included (15 males, 64.31 ± 10.73 years), 16/32 scanned with the Siemens system (cohort 1) and 16/32 with the GE system (cohort 2). In signal-to-signal, all algorithms capture salient characteristics of the diffusion-T2 decay (Fig. S2 in the Supplemental Material) and of anatomical features (mean relative errors below 12%; Fig. 1b; Table S1 and Figs. S3 and S4 in the Supplemental Material). T2-IVIM-Kurtosis maps fitted to the signal-to-signal output show less variability between algorithms than those predicted from maps-to-maps. K $$ K $$ and T 2 t $$ T2t $$ are qualitatively worse in maps-to-maps (Fig. 1c). Biopsies reveals the existence of a variety of intra-tumor cellular characteristics (eg, active cancer and necrosis). All MRI metrics (both clinical and advanced) reveal intra-tumoral heterogeneity, mirroring the histological ground truth. However, advanced metrics such as K $$ K $$ and T 2 t $$ T2t $$ enable the quantification of non-Gaussian diffusion and T2 relaxation, potentially giving extra information than protocols not including high b and multiple TE (Fig. 1d; Fig. S5 in the Supplemental Material). Mean BI and DI are lower for signal-to-signal than maps-to-maps. A greater variation is seen between metrics than between algorithms, and such variation is pronounced in maps-to-maps. In general, ML algorithms achieve better performances in cohort 1 than 2 (lower BI and DI; Fig. 2a; Figs. S6 and S7 in the Supplemental Material). No statistical differences between algorithms are seen, for a fixed prediction strategy (Fig. S8 in the Supplemental Material). Pixel-level correlations between reference and predicted DR signals are above 0.8 for both cohorts but lower correlations are seen between reference and predicted metrics (Fig. S9 in the Supplemental Material). BI and DI decrease as the training size increases. It stabilizes around N = 5 patients. mlNN exhibits low BI and DI even with only N = 2 training cases. DI's fluctuations in the range 5–15 patients are mainly caused by D v $$ {D}_v $$ (Fig. 2b; Fig. S11 in the Supplemental Material). We investigated whether ML can enhance the amount of information on tissue microstructure that can be extracted from clinically viable dMRI scans. It appears feasible to gain insight on DR properties from shorter dMRI protocols at fixed TE in advanced solid tumors, using small training cohorts. To achieve this, predicting rich DR protocols and then fitting advanced signal models on the predicted signals provides substantially better performances than predicting DR maps directly. In practice, training cohorts as small as N = 5 scans may suffice for this purpose, and independently of the specific algorithm used for prediction. Therefore, we recommend that efforts of the community should focus on the signal prediction, rather than on the unseen parametric maps. We acknowledge some limitations of our approach. First, we did not consider advanced deep learning algorithms, for example, vision transformers, which we will study in future work. Second, here we only provide a first pilot demonstration, which we aim to confirm in larger cohorts, and in data from more MRI scanners and acquisition protocols, beyond DR imaging. For DR quantification in abdominal and pelvic solid tumors, using ML to enhance the information that can be extracted from clinical dMRI protocols appears feasible, with practical training sets of as few as five scans. We thank the whole medical oncology, radiology, pathology, molecular biology, clinical trial, and IT teams at the Vall d'Hebron Campus. We would also like to express our sincere gratitude to all patients and their families for dedicating their time to research. VHIO acknowledges the State Agency for Research (Agencia Estatal de Investigación) for the financial support as a Center of Excellence Severo Ochoa (CEX2020-001024-S/AEI/10.13039/501100011033), the Cellex Foundation for providing research facilities and equipment and the CERCA Programme from the Generalitat de Catalunya for their support. This research has been supported by PREdICT, sponsored by AstraZeneca. This study has been co-funded by the European Regional Development Fund/European Social Fund “A way to make Europe” (to R.P.L.). RPL is supported by “la Caixa” Foundation, the Prostate Cancer Foundation (18YOUN19), a CRIS Foundation Talent Award (TALENT19-05), the FERO Foundation through the XVIII Fero Fellowship for Oncological Research, the Instituto de Salud Carlos III-Investigación en Salud (PI18/01395 and PI21/01019), the Asociación Española Contra el Cancer (AECC) (PRYCO211023SERR) and the Agency for Management of University and Research Grants of Catalonia (AGAUR) (2023PROD00178). This research has been funded by the CaixaResearch Advanced Oncology Research Program supported by “La Caixa” Foundation (to R.P.L.). The project that gave rise to these results received the support of a fellowship from “la Caixa” Foundation (ID 100010434). The fellowship code is “LCF/BQ/PR22/11920010”, funding F.G. This research has received support from the Beatriu de Pinós Postdoctoral Program from the Secretariat of Universities and Research of the Department of Business and Knowledge of the Government of Catalonia, and the support from the Marie Sklodowska-Curie COFUND program (BP3, contract number 801370; reference 2019 BP 00182) of the H2020 program (to K.B.). C.M. is supported by the Asociación Española Contra el Cancer (PRYCO211023SERR). VHIO is also grateful to the Generalitat de Catalunya, Comissió Interdepartamental de Recerca i Innovació Tecnològica. Data acquisition was sponsored by AstraZeneca (AZ). MVid works for Siemens. PGPG works for GE. KB worked as a researcher at VHIO, and is now an employee of AZ. AZ, Siemens and GE did not influence the design of the study; the experiments and analysis; the interpretation of data and results; manuscript writing; the decision to submit the manuscript in its present form for publication; or any other aspect concerning this article. Data S1: Supporting Information. Please note: The publisher is not responsible for the content or functionality of any supporting information supplied by the authors. Any queries (other than missing content) should be directed to the corresponding author for the article.
BibTeX
@article{macarro2024enhancing,
author = {Carlos Macarro and Kinga Bernatowicz and Alonso García-Ruiz and Garazi Serna and Camilo Monreal‐Agüero and S. Simonetti and Matteo Figini and Juan Francisco Corral and Valezka Garay and Marta Vidorreta and Pablo García‐Polo García and Xavier Merino and Richard Mast and Núria Rosón and María Vieito and Manuel Escobar and Daniel C. Alexander and Rodrigo A. Toledo and Paolo Nucíforo and Elena Garralda and Raquel Pérez-López and Francesco Grussu},
title = {{Enhancing Tumor Microstructural Quantification With Machine Learning and Diffusion‐Relaxation <scp>MRI</scp>}},
journal = {Journal of Magnetic Resonance Imaging},
year = {2024},
doi = {10.1002/jmri.29484},
}Ask Althea to put this paper to the test.
Loading related content...